fujitsu-optical-tributary-signal

This module contains YANG definitions for the Optical Transport Interfaces. Copyright (c) 2015 Fujitsu Network Communications, ...

  • Version: 2018-09-19

    fujitsu-optical-tributary-signal@2018-09-19


    
      module fujitsu-optical-tributary-signal {
    
        yang-version 1;
    
        namespace
          "urn:fujitsu:params:xml:ns:yang:interface:otsi";
    
        prefix otsi;
    
        import ietf-interfaces {
          prefix if;
        }
        import fujitsu-state-timer {
          prefix st;
        }
        import fujitsu-entity-states {
          prefix entity-states;
        }
        import fujitsu-if-type {
          prefix fjift;
        }
    
        organization "Fujitsu Ltd.";
    
        contact
          "Fujitsu Ltd.
         
         Address: 2801 Telecom Parkway
                  Richardson, Texas 75082
         
         Tel: +1-800-USE-FTAC (1-800-873-3822)
         Email: ftac@fnc.fujitsu.com
         Web: www.fujitsu.com/us/services/telecom";
    
        description
          "This module contains YANG definitions 
         for the Optical Transport Interfaces.
         
         Copyright (c) 2015 Fujitsu Network Communications, inc.
         All rights reserved. ";
    
        revision "2018-09-19" {
          description
            "Added sdfec2 fec attribute.";
        }
    
        revision "2018-06-13" {
          description
            "Added sdfec5 and sdfec6 fec attributes.";
        }
    
        revision "2018-04-09" {
          description
            "Accomodating OtsiV2 attributes.";
        }
    
        revision "2016-10-17" {
          description
            "1. Added Frequency range for center-frequency and center-frequency-rx.
           2. Renamed NLC Parameters";
        }
    
        revision "2015-04-10" {
          description "Initial revision.";
        }
    
    
        grouping otsi-attributes {
          description
            "Optical Tributary Signal attributes (OTSI)";
          uses entity-states:oper-status;
    
          uses entity-states:admin-status {
            refine admin-status {
              default "down";
              mandatory false;
            }
          }
    
          leaf act-laser {
            type enumeration {
              enum "normal" {
                value 0;
              }
              enum "shutdown" {
                value 1;
              }
              enum "none" {
                value 2;
              }
            }
          }
    
          leaf center-frequency {
            type decimal64 {
              fraction-digits 5;
              range "0 | 191.35000..196.10000";
            }
            units "THz";
            description
              "Frequency of the transmit optical channel.";
          }
    
          leaf lambda {
            type decimal64 {
              fraction-digits 2;
            }
            units "nm";
            description
              "Lambda corresponding to transmit frequency.";
          }
    
          leaf center-frequency-rx {
            type decimal64 {
              fraction-digits 5;
              range "0 | 191.35000..196.10000";
            }
            units "THz";
            description
              "Frequency of the receive optical channel.";
          }
    
          leaf lambda-rx {
            type decimal64 {
              fraction-digits 2;
            }
            units "nm";
            description
              "Lambda corresponding to receive frequency.";
          }
    
          leaf circuit-id {
            type string {
              length "0..45";
            }
            description
              "Circuit identifier/user label.";
          }
    
          leaf slot-width {
            type decimal64 {
              fraction-digits 2;
            }
            units "GHz";
            description
              "Channel slot width in GHz.";
          }
    
          leaf param-A {
            type boolean;
            description "";
          }
    
          leaf param-B {
            type boolean;
            description "";
          }
    
          leaf param-C {
            type uint32;
            description "";
          }
    
          leaf param-D {
            type uint32;
            description "";
          }
    
          leaf param-E {
            type uint32;
            description "";
          }
    
          leaf param-F {
            type uint32;
            description "";
          }
    
          leaf param-G {
            type uint32;
            description "";
          }
    
          leaf param-H {
            type uint32;
            description "";
          }
    
          leaf param-I {
            type uint32;
            description "";
          }
    
          leaf param-J {
            type decimal64 {
              fraction-digits 4;
            }
            description "";
          }
    
          leaf param-K {
            type decimal64 {
              fraction-digits 4;
            }
            description "";
          }
    
          leaf param-L {
            type decimal64 {
              fraction-digits 4;
            }
            description "";
          }
    
          leaf param-M {
            type uint32;
            description "";
          }
        }  // grouping otsi-attributes
    
        identity otucn-nw-rate-identity {
          description
            "A unique rate identification of the OTUCn.";
        }
    
        identity R600G {
          base otucn-nw-rate-identity;
          description
            "Identity for 600G NW Rate.";
        }
    
        identity R500G {
          base otucn-nw-rate-identity;
          description
            "Identity for 500G NW Rate.";
        }
    
        identity R400G {
          base otucn-nw-rate-identity;
          description
            "Identity for 400G NW Rate.";
        }
    
        identity R300G {
          base otucn-nw-rate-identity;
          description
            "Identity for 300G NW Rate.";
        }
    
        identity R200G {
          base otucn-nw-rate-identity;
          description
            "Identity for 200G NW Rate.";
        }
    
        identity R100G {
          base otucn-nw-rate-identity;
          description
            "Identity for 100G NW Rate.";
        }
    
        grouping otsiv2-attributes {
          description
            "Optical Tributary Signal V2 attributes (OTSIV2)";
          leaf ais-pt {
            type enumeration {
              enum "ais-shutdown" {
                value 1;
              }
              enum "ais-none" {
                value 2;
              }
            }
            description
              "Alarm transfer setting for Alarm Indication Signal.";
          }
    
          leaf transmit-power {
            type decimal64 {
              fraction-digits 2;
              range "-5.00..1.00";
            }
            units "dBm";
            description
              "Transmit power setting.";
          }
    
          leaf otsi-rate {
            type identityref {
              base otucn-nw-rate-identity;
            }
            description "Network rate.";
          }
    
          leaf modulation-format {
            type enumeration {
              enum "bpsk" {
                value 1;
                description
                  "Binary phase-shift keying.";
              }
              enum "dc-dp-bpsk" {
                value 2;
                description
                  "DC dual-polarization binary phase-shift keying.";
              }
              enum "qpsk" {
                value 3;
                description
                  "Quadrature phase-shift keying.";
              }
              enum "dp-qpsk" {
                value 4;
                description
                  "Dual-polarization binary phase-shift keying.";
              }
              enum "qam16" {
                value 5;
                description
                  "Quadrature amplitude modulation 16.";
              }
              enum "dp-qam16" {
                value 6;
                description
                  "Dual-polarization quadrature amplitude modulation 16.";
              }
              enum "dp-qam32" {
                value 7;
                description
                  "Dual-polarization quadrature amplitude modulation 32.";
              }
              enum "dp-qam64" {
                value 8;
                description
                  "Dual-polarization quadrature amplitude modulation 64.";
              }
              enum "dc-dp-qam16" {
                value 9;
                description
                  "DC dual-polarization quadrature amplitude modulation 16.";
              }
              enum "qam8" {
                value 10;
                description
                  "Quadrature amplitude modulation 8.";
              }
              enum "dp-qam8" {
                value 11;
                description
                  "Dual-polarization quadrature amplitude modulation 8.";
              }
              enum "dc-dp-qam8" {
                value 12;
                description
                  "DC dual-polarization quadrature amplitude modulation 8.";
              }
              enum "8psk" {
                value 13;
                description
                  "Phase shift keying with 8 states.";
              }
              enum "8psk-2" {
                value 14;
                description
                  "Phase shift keying with 8 states - 2.";
              }
            }
            description "Modulation format.";
          }
    
          leaf fec {
            type enumeration {
              enum "hpdfec1" {
                value 1;
                description
                  "25% Soft Decision FEC.";
              }
              enum "hpdfec2" {
                value 2;
                description
                  "20% Soft Decision FEC.";
              }
              enum "sdfec3" {
                value 3;
                description
                  "Soft Decision FEC 3.";
              }
              enum "sdfec4" {
                value 4;
                description
                  "Soft Decision FEC 4.";
              }
              enum "sdfec5" {
                value 5;
                description
                  "Soft Decision FEC 5.";
              }
              enum "sdfec6" {
                value 6;
                description
                  "Soft Decision FEC 6.";
              }
              enum "sdfec2" {
                value 7;
                description
                  "Soft Decision FEC 2.";
              }
            }
            description "FEC mode.";
          }
    
          leaf roadm-type {
            type enumeration {
              enum "CD" {
                value 1;
                description
                  "Colourless Directionless  degree is applicable.";
              }
              enum "AWG" {
                value 2;
                description
                  "Arrayed Wave Guide/DIRECT degree is applicable.";
              }
            }
            default "CD";
            description "Setting of ROADM type.";
          }
    
          leaf confmode-type {
            type enumeration {
              enum "100GONLY" {
                value 1;
                description
                  "100GONLY if the ROADM systems degree, to which this PIU is connected, carries only 100G wavelengths.";
              }
              enum "10GMIX" {
                value 2;
                description
                  "10GMIX if the ROADM systems degree, to which this PIU is connected, carries 10G wavelengths along with 100G wavelengths.";
              }
            }
            default "100GONLY";
            description
              "Config Mode is a setting to get the best optical reach.";
          }
    
          leaf nyquist {
            type enumeration {
              enum "ON" {
                value 1;
              }
              enum "OFF" {
                value 2;
              }
            }
            description
              "Current status of Nyquist filter mode.";
          }
    
          leaf direction {
            type enumeration {
              enum "uni-rx" {
                value 1;
                description
                  "Unidirectional receive only.";
              }
              enum "uni-tx" {
                value 2;
                description
                  "Unidirectional transmit only.";
              }
              enum "bi" {
                value 3;
                description "Bidirectional.";
              }
            }
            description "Otsi Direction.";
          }
        }  // grouping otsiv2-attributes
    
        augment /if:interfaces/if:interface {
          container otsi {
            when
              "(../if:type = 'fjift:fujitsuOtsi') or (../if:type = 'fjift:fujitsuOtsiV2')";
            presence
              "Attribute Nodes for Optical Transport Signal (otsi)";
            description
              "Optical Tributary Signal attributes (OTSI) Models the optical channel interfaces for an Optical White Box.
             Otsi Types:
             fujitsuOtsi    - expected supporting entity is otsig
             fujitsuOtsiV2  - expected supporting entity is port.
            ";
            uses st:state-timer {
              refine actual-vstimer {
                config false;
              }
            }
    
            uses otsi-attributes {
              refine oper-status {
                config false;
              }
    
              refine lambda {
                config false;
              }
    
              refine lambda-rx {
                config false;
              }
    
              refine act-laser {
                config false;
              }
            }
    
            uses otsiv2-attributes {
              refine nyquist {
                config false;
              }
            }
          }  // container otsi
        }
    
        notification otsi-notif {
          leaf name {
            type leafref {
              path "/if:interfaces/if:interface/if:name";
            }
            description
              "Otsi interface name for Notifications.";
          }
    
          container otsi {
            uses st:state-timer;
    
            uses otsi-attributes;
    
            uses otsiv2-attributes;
          }  // container otsi
        }  // notification otsi-notif
      }  // module fujitsu-optical-tributary-signal
    