This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on subscriber management v...
Version: 2023-12-15
module bbf-pppoe-intermediate-agent-profile-common { yang-version 1.1; namespace "urn:bbf:yang:bbf-pppoe-intermediate-agent-profile-common"; prefix bbf-pppoe-ia-pc; import bbf-yang-types { prefix bbf-yang; } import bbf-subscriber-types { prefix bbf-subtype; } organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Nick Hancock, Adtran Editor: Ludwig Pauwels, Nokia PS Leader: Joey Boyd, Adtran WA Director: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia"; description "This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on subscriber management via the PPPoE protocol as applicable to access network equipment. As such, this module is specific to access network equipment (e.g., BBF-specified Access Nodes and FTTdp DPUs). Specifically, this module contains the definition of a profile for subscriber information used by a PPPoE Intermediate Agent in creating an Agent Circuit ID and Remote ID as described in TR-101i2. Copyright (c) 2017-2023, Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-383a7; see the TR itself for full legal notices."; revision "2023-12-15" { description "Amendment 7. * Approval Date: 2023-12-15. * Publication Date: 2023-12-15."; reference "TR-383a7: Common YANG Modules <https://www.broadband-forum.org/technical/download/ TR-383_Amendment-7.pdf>"; } grouping pppoe-profiles { description "PPPoE Intermediate Agent configuration profiles."; container pppoe-profiles { description "PPPoE Intermediate Agent configuration profiles."; list pppoe-profile { key "name"; description "A PPPoE Intermediate Agent configuration profile."; leaf name { type bbf-yang:string-ascii64; description "Name of the profile."; } container pppoe-vendor-specific-tag { description "Contains information that needs to be filled in the vendor-specific tag - 0x0105."; leaf-list subtag { type enumeration { enum "circuit-id" { value 0; description "Add the sub-option Agent Circuit ID in the vendor- specific tag with sub-option number 0x01. The value inserted is the value of the leaf 'circuit-id' defined in the instance in the '/bbf-subprof:subscriber-profiles/bbf-subprof: subscriber-profile' that is associated with the interface, if any. If this leaf is unknown, then a sub-option Agent Circuit ID will be generated according to the syntax defined in 'default-circuit-id-syntax'."; reference "TR-101i2 Section 8.3"; } enum "remote-id" { value 1; description "Add the sub-option Agent Remote ID in the vendor-specific tag with sub-option number 0x02. The value inserted is the value of the leaf 'remote-id' defined in the instance in the '/bbf-subprof:subscriber-profiles/bbf-subprof: subscriber-profile' that is associated with the interface, if any. If this leaf is unknown, then a sub-option Agent Remote ID will be generated according to the syntax defined in 'default-remote-id-syntax'."; reference "TR-101i2 Section 8.3"; } enum "access-loop-characteristics" { value 2; description "Access loop characteristics to be added in the vendor-specific tag with sub-tag-numbers 0x81-0x8E and 0x90. The characteristics to be added to the sub-option are controlled via 'access-loop-subtags'."; reference "TR-101i2 Section 8.4"; } } min-elements 1; description "Identifies the sub-tags that should be part of the vendor-specific tag."; } leaf default-circuit-id-syntax { type bbf-yang:string-ascii63-or-empty; default ""; description "To be used to generate a sub-option Agent Circuit ID when no 'circuit-id' is provided for the VLAN sub-interface via a referenced '/bbf-subprof: subscriber-profiles/bbf-subprof:subscriber-profiles'. The syntax is a string of ASCII characters that determines the actual value inserted in the sub- option. Parts of the syntax that are recognized as predefined keywords will be replaced by an actual value."; reference "TR-178 R-117"; } leaf default-remote-id-syntax { type bbf-yang:string-ascii63-or-empty; default ""; description "To be used to generate a sub-option Agent Remote ID when no 'remote-id' is provided for the VLAN sub- interface via a referenced '/bbf-subprof: subscriber-profiles/bbf-subprof:subscriber-profile'. The syntax is a string of ASCII characters that determines the actual value inserted in the sub- option. Parts of the syntax that are recognized as predefined keywords will be replaced by an actual value."; reference "TR-178 R-120"; } leaf access-loop-subtags { type bbf-subtype:broadband-line-characteristics; default ""; description "Access Loop sub-tags that are to be added in the vendor-specific tag."; reference "TR-178 R-123"; } leaf start-numbering-from-zero { type boolean; default "false"; description "In case the 'default-circuit-id-syntax' or 'default-remote-id-syntax' indicates a Slot or a Port identification shall be added to the sub-tag value, then this leaf determines if the slot/port numbering must start from 0 or 1."; reference "TR-178 R-118"; } leaf use-leading-zeroes { type boolean; default "false"; description "In case the 'default-circuit-id-syntax' or 'default-remote-id-syntax' indicates a Slot or a Port identification shall be added to the sub-tag value, then this leaf determines if the slot/port numbering must use leading 0's or not, i.e., generate a fixed- length string or a string with only meaningful digits. Note that the number of digits used to form the fixed- length string is device specific. A device may use the number of digits as specified in TR-101i2 Table 2/ TR-156 Table 1 or a device may determine the number of digits by the maximum value for the Slot or a Port identification applicable to the device, i.e., if the maximum value is less than or equal to 9, one digit may be used; if the maximum value is less than or equal to 99, two digits may be used, etc."; reference "TR-178 R-119; TR-101i2 R-153; TR-101i2 Table 2; TR-156 Table 1"; } list padding { key "name"; description "Configures how to insert values in an actual circuit-id and/or remote-id string. In other words, when the syntax 'default-circuit-id-syntax' or 'default-remote-id-syntax' is used to generate an actual string, and the syntax contains a pre-defined keyword, then an entity in this 'padding' list with this pre-defined keyword as 'name' determines how the value shall be generated and inserted in the string. Configuring an entry for a particular keyword means: - for the keywords 'Slot' and 'Port' (or for functional equivalent keywords, as exact keyword values are not standardized): this configuration overrules the configuration of the data node 'use-leading-zeroes' configured in the sibling data node to this list. - for any other keyword: the system adds or does not add leading zeros as configured for this keyword. Not configuring an entry for a particular keyword means: - for the keywords 'Slot' and 'Port' (or for functional equivalent keywords): the system behaves as configured in 'use-leading-zeroes' configured in the sibling data node to this list. - for any other keyword: the possible use of leading zeros is system dependent."; leaf name { type bbf-yang:string-ascii64; description "A pre-defined keyword that can be used in the string 'default-circuit-id-syntax' and/or 'default-remote-id-syntax'."; } leaf use-leading-zeroes { type boolean; description "This data node indicates whether or not leading zeros shall be used when generating a value for a pre- defined keyword in the 'default-circuit-id-syntax' or 'default-remote-id-syntax'. When leading zeros shall be used the device shall generate a fixed-length string. When no leading zeros shall be inserted, then a string with only meaningful digits is generated. Note that the number of digits used to form the fixed-length string is device specific. A device may use the number of digits as specified in TR-101i2 Table 2 / TR-156 Table 1 or a device may determine the number of digits by the maximum value it can have. For example, if the maximum value for the number of Slots in a device is less than or equal to 9, one digit may be used; if the maximum value is less than or equal to 99, two digits may be used, etc."; reference "TR-178 R-119; TR-101i2 R-153; TR-101i2 Table 2; TR-156 Table 1"; } } // list padding } // container pppoe-vendor-specific-tag } // list pppoe-profile } // container pppoe-profiles } // grouping pppoe-profiles } // module bbf-pppoe-intermediate-agent-profile-common
© 2023 YumaWorks, Inc. All rights reserved.