This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on the management of subsc...
Version: 2023-12-15
module bbf-subscriber-types { yang-version 1.1; namespace "urn:bbf:yang:bbf-subscriber-types"; prefix bbf-subtype; organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Nick Hancock, Adtran Editor: Ludwig Pauwels, Nokia PS Leader: Joey Boyd, Adtran WA Director: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia"; description "This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on the management of subscribers as applicable to access network equipment. As such, this module is specific to access network equipment (e.g., BBF-specified Access Nodes and FTTdp DPUs). Specifically, this module defines common types associated with subscribers and subscriber protocols. Copyright (c) 2017-2023, Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-383a7; see the TR itself for full legal notices."; revision "2023-12-15" { description "Amendment 7. * Approval Date: 2023-12-15. * Publication Date: 2023-12-15."; reference "TR-383a7: Common YANG Modules <https://www.broadband-forum.org/technical/download/ TR-383_Amendment-7.pdf>"; } revision "2022-03-01" { description "Amendment 5. * Approval Date: 2022-03-01. * Publication Date: 2022-03-01."; reference "TR-383a5: Common YANG Modules <https://www.broadband-forum.org/technical/download/ TR-383_Amendment-5.pdf>"; } revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13. * Publication Date: 2020-10-13."; reference "TR-383a3: Common YANG Modules <https://www.broadband-forum.org/technical/download/ TR-383_Amendment-3.pdf>"; } revision "2017-05-08" { description "Initial revision. * Approval Date: see revision date above. * Publication Date: 2017-06-02."; reference "TR-383: Common YANG Modules <https://www.broadband-forum.org/technical/download/ TR-383.pdf>"; } typedef broadband-line-characteristics { type bits { bit actual-data-rate-upstream { position 0; description "Sub-option type 0x81 - Actual upstream data rate of an access loop."; reference "TR-101i2 Table 3 - subopt. 0x81; ITU-T G.997.1 Clause 7.5.2.1 - Actual data rate; TR-301i2 Table 14-1 - Sub-TLV 129; ITU-T G.997.2 Clause 7.11.1.1 - Net data rate upstream (NDRus)"; } bit actual-data-rate-downstream { position 1; description "Sub-option type 0x82 - Actual downstream data rate of an access loop."; reference "TR-101i2 Table 3 - subopt. 0x82; ITU-T G.997.1 Clause 7.5.2.1 - Actual data rate; TR-301i2 Table 14-1 - Sub-TLV 130; ITU-T G.997.2 Clause 7.11.1.1 - Net data rate downstream (NDRds)"; } bit min-data-rate-upstream { position 2; description "Sub-option type 0x83 - Minimum upstream data rate at which the loop is set to operate."; reference "TR-101i2 Table 3 - subopt. 0x83; ITU-T G.997.1 Clause 7.3.2.1.1 - Minimum data rate"; } bit min-data-rate-downstream { position 3; description "Sub-option type 0x84 - Minimum downstream data rate at which the loop is set to operate."; reference "TR-101i2 Table 3 - subopt. 0x84; ITU-T G.997.1 Clause 7.3.2.1.1 - Minimum data rate"; } bit attainable-data-rate-upstream { position 4; description "Sub-option type 0x85 - Maximum upstream data rate that can be achieved."; reference "TR-101i2 Table 3 - subopt. 0x85; ITU-T G.997.1 Clause 7.5.1.20 - Upstream maximum attainable data rate (ATTNDRus); TR-301i2 Table 14-1 - Sub-TLV 133; ITU-T G.997.2 Clause 7.11.2.1 - Attainable net data rate upstream (ATTNDRus)"; } bit attainable-data-rate-downstream { position 5; description "Sub-option type 0x86 - Maximum downstream data rate that can be achieved."; reference "TR-101i2 Table 3 - subopt. 0x86; ITU-T G.997.1 Clause 7.5.1.19 - Downstream maximum attainable data rate (ATTNDRds); TR-301i2 Table 14-1 - Sub-TLV 134; ITU-T G.997.2 Clause 7.11.2.1 - Attainable net data rate downstream (ATTNDRds)"; } bit max-data-rate-upstream { position 6; description "Sub-option type 0x87 - Maximum upstream data rate at which the loop is set to operate."; reference "TR-101i2 Table 3 - subopt. 0x87; ITU-T G.997.1 Clause 7.3.2.1.3 - Maximum data rate"; } bit max-data-rate-downstream { position 7; description "Sub-option type 0x88 - Maximum downstream data rate at which the loop is set to operate."; reference "TR-101i2 Table 3 - subopt. 0x88; ITU-T G.997.1 Clause 7.3.2.1.3 - Maximum data rate"; } bit min-data-rate-upstream-low-power-state { position 8; description "Sub-option type 0x89 - Minimum upstream data rate at which the loop is set to operate during the low power state (L1/L2)."; reference "TR-101i2 Table 3 - subopt. 0x89; ITU-T G.997.1 Clause 7.3.2.1.5 - Minimum data rate in low power state"; } bit min-data-rate-downstream-low-power-state { position 9; description "Sub-option type 0x8A - Minimum downstream data rate at which the loop is set to operate during the low power state (L1/L2)."; reference "TR-101i2 Table 3 - subopt. 0x8A; ITU-T G.997.1 Clause 7.3.2.1.5 - Minimum data rate in low power state"; } bit max-interleaving-delay-upstream { position 10; description "Sub-option type 0x8B - Maximum one-way interleaving delay in upstream."; reference "TR-101i2 Table 3 - subopt. 0x8B; ITU-T G.997.1 Clause 7.3.2.2 - Maximum interleaving delay"; } bit actual-interleaving-delay-upstream { position 11; description "Sub-option type 0x8C - Actual one-way interleaving delay value in milliseconds corresponding to the interleaver setting in upstream."; reference "TR-101i2 Table 3 - subopt. 0x8C; ITU-T G.997.1 Clause 7.5.2.3 - Actual delay"; } bit max-interleaving-delay-downstream { position 12; description "Sub-option type 0x8D - Maximum one-way interleaving delay in downstream."; reference "TR-101i2 Table 3 - subopt. 0x8D; ITU-T G.997.1 Clause 7.3.2.2 - Maximum interleaving delay"; } bit actual-interleaving-delay-downstream { position 13; description "Sub-option type 0x8E - Actual one-way interleaving delay value in milliseconds corresponding to the interleaver setting in downstream."; reference "TR-101i2 Table 3 - subopt. 0x8E; ITU-T G.997.1 Clause 7.5.2.3 - Actual delay"; } bit access-loop-encapsulation { position 14; description "Sub-option type 0x90 - the data link protocol and the encapsulation overhead on the access loop."; reference "TR-101i2 R-164"; } bit expected-throughput-upstream { position 15; description "Expected throughput (ETR) upstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 155; ITU-T G.997.2 Clause 7.11.1.2 - Expected throughput upstream (ETRus)"; } bit expected-throughput-downstream { position 16; description "Expected throughput (ETR) downstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 156; ITU-T G.997.2 Clause 7.11.1.2 - Expected throughput downstream (ETRds)"; } bit attainable-expected-throughput-upstream { position 17; description "Attainable expected throughput (ATTETR) upstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 157; ITU-T G.997.2 Clause 7.11.2.2 - Attainable expected throughput upstream (ATTETRus)"; } bit attainable-expected-throughput-downstream { position 18; description "Attainable expected throughput (ATTETR) downstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 158; ITU-T G.997.2 Clause 7.11.2.2 - Attainable expected throughput downstream (ATTETRds)"; } bit gamma-data-rate-upstream { position 19; description "Gamma data rate (GDR) upstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 159; ITU-T G.997.2 Clause 7.11.1.3 - Gamma Data Rate upstream (GDRus)"; } bit gamma-data-rate-downstream { position 20; description "Gamma data rate (GDR) downstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 160; ITU-T G.997.2 Clause 7.11.1.3 - Gamma Data Rate downstream (GDRds)"; } bit attainable-gamma-data-rate-upstream { position 21; description "Attainable gamma data rate (ATTGDR) upstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 161; ITU-T G.997.2 Clause 7.11.2.3 - Attainable gamma data rate upstream (ATTGDRus)"; } bit attainable-gamma-data-rate-downstream { position 22; description "Attainable gamma data rate (ATTGDR) downstream."; reference "TR-301i2 Table 14-1 - Sub-TLV 162; ITU-T G.997.2 Clause 7.11.2.3 - Attainable gamma data rate downstream (ATTGDRds)"; } } description "The type defined for the broadband line characteristics listed in TR-101i2 and TR-301i2."; reference "TR-101i2 R-158; TR-301i2 R-119"; } } // module bbf-subscriber-types
© 2023 YumaWorks, Inc. All rights reserved.