openconfig-alarms

This module defines operational state data related to alarms that the device is reporting. This model reuses some data items de...

  • Version: 2017-08-24

    openconfig-alarms@2017-08-24


    
      module openconfig-alarms {
    
        yang-version 1;
    
        namespace
          "http://openconfig.net/yang/alarms";
    
        prefix oc-alarms;
    
        import openconfig-extensions {
          prefix oc-ext;
        }
        import openconfig-types {
          prefix oc-types;
        }
        import openconfig-platform {
          prefix oc-platform;
        }
    
        organization "OpenConfig working group";
    
        contact
          "OpenConfig working group
        www.openconfig.net";
    
        description
          "This module defines operational state data related to alarms
        that the device is reporting.
    
        This model reuses some data items defined in the draft IETF
        YANG Alarm Module:
        https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02
    
        Portions of this code were derived from the draft IETF YANG Alarm
        Module. Please reproduce this note if possible.
    
        IETF code is subject to the following copyright and license:
        Copyright (c) IETF Trust and the persons identified as authors of
        the code.
        All rights reserved.
    
        Redistribution and use in source and binary forms, with or without
        modification, is permitted pursuant to, and subject to the license
        terms contained in, the Simplified BSD License set forth in
        Section 4.c of the IETF Trust's Legal Provisions Relating
        to IETF Documents (http://trustee.ietf.org/license-info).";
    
        revision "2017-08-24" {
          description "Initial public release";
          reference
            "0.1.0";
    
        }
    
        oc-ext:openconfig-version "0.1.0";
    
        identity OPENCONFIG_ALARM_TYPE_ID {
          description
            "Base identity for alarm type ID profiles";
        }
    
        identity AIS {
          base OPENCONFIG_ALARM_TYPE_ID;
          description
            "Defines an alarm indication signal type of alarm";
        }
    
        identity EQPT {
          base OPENCONFIG_ALARM_TYPE_ID;
          description
            "Defines an equipment related type of alarm that is specific
           to the physical hardware";
        }
    
        identity LOS {
          base OPENCONFIG_ALARM_TYPE_ID;
          description
            "Defines a loss of signal type of alarm";
        }
    
        identity OTS {
          base OPENCONFIG_ALARM_TYPE_ID;
          description
            "Defines a optical transport signal type of alarm";
        }
    
        identity OPENCONFIG_ALARM_SEVERITY {
          description
            "Base identity for alarm severity profiles. Derived
          identities are based on contents of the draft
          IETF YANG Alarm Module";
          reference
            "IETF YANG Alarm Module: Draft - typedef severity
            https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
        }
    
        identity UNKNOWN {
          base OPENCONFIG_ALARM_SEVERITY;
          description
            "Indicates that the severity level could not be determined.
          This level SHOULD be avoided.";
        }
    
        identity MINOR {
          base OPENCONFIG_ALARM_SEVERITY;
          description
            "Indicates the existence of a non-service affecting fault
          condition and that corrective action should be taken in
          order to prevent a more serious (for example, service
          affecting) fault. Such a severity can be reported, for
          example, when the detected alarm condition is not currently
          degrading the capacity of the resource";
        }
    
        identity WARNING {
          base OPENCONFIG_ALARM_SEVERITY;
          description
            "Indicates the detection of a potential or impending service
          affecting fault, before any significant effects have been felt.
          Action should be taken to further diagnose (if necessary) and
          correct the problem in order to prevent it from becoming a more
          serious service affecting fault.";
        }
    
        identity MAJOR {
          base OPENCONFIG_ALARM_SEVERITY;
          description
            "Indicates that a service affecting condition has developed
          and an urgent corrective action is required. Such a severity
          can be reported, for example, when there is a severe
          degradation in the capability of the resource and its full
          capability must be restored.";
        }
    
        identity CRITICAL {
          base OPENCONFIG_ALARM_SEVERITY;
          description
            "Indicates that a service affecting condition has occurred
          and an immediate corrective action is required. Such a
          severity can be reported, for example, when a resource becomes
          totally out of service and its capability must be restored.";
        }
    
        grouping alarm-state {
          description
            "Operational state data for device alarms";
          leaf resource {
            type string;
            description
              "The item that is under alarm within the device. The
            resource may be a reference to an item which is
            defined elsewhere in the model. For example, it
            may be a platform/component, interfaces/interface,
            terminal-device/logical-channels/channel, etc. In this
            case the system should match the name of the referenced
            item exactly. The referenced item could alternatively be
            the path of the item within the model.";
            reference
              "IETF YANG Alarm Module: Draft - typedef resource
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf text {
            type string;
            description
              "The string used to inform operators about the alarm. This
             MUST contain enough information for an operator to be able
             to understand the problem. If this string contains structure,
             this format should be clearly documented for programs to be
             able to parse that information";
            reference
              "IETF YANG Alarm Module: Draft - typedef alarm-text
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf time-created {
            type oc-types:timeticks64;
            description
              "The time at which the alarm was raised by the system.
            This value is expressed as nanoseconds since the Unix Epoch";
          }
    
          leaf severity {
            type identityref {
              base OPENCONFIG_ALARM_SEVERITY;
            }
            description
              "The severity level indicating the criticality and impact
            of the alarm";
            reference
              "IETF YANG Alarm Module: Draft - typedef severity
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf type-id {
            type union {
              type string;
              type identityref {
                base OPENCONFIG_ALARM_TYPE_ID;
              }
            }
            description
              "The abbreviated name of the alarm, for example LOS,
            EQPT, or OTS. Also referred to in different systems as
            condition type, alarm identifier, or alarm mnemonic. It
            is recommended to use the OPENCONFIG_ALARM_TYPE_ID
            identities where possible and only use the string type
            when the desired identityref is not yet defined";
            reference
              "IETF YANG Alarm Module: Draft - typedef alarm-type-id
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
        }  // grouping alarm-state
    
        grouping alarm-config {
          description
            "Configuration data for device alarms";
          leaf id {
            type string;
            description
              "Unique ID for the alarm -- this will not be a
            configurable parameter on many implementations";
          }
        }  // grouping alarm-config
    
        grouping alarms-top {
          description
            "Top-level grouping for device alarms";
          container alarms {
            description
              "Top-level container for device alarms";
            list alarm {
              key "id";
              description
                "List of alarms, keyed by a unique id";
              leaf id {
                type leafref {
                  path "../config/id";
                }
                description
                  "References the unique alarm id";
              }
    
              container config {
                description
                  "Configuration data for each alarm";
                uses alarm-config;
              }  // container config
    
              container state {
                config false;
                description
                  "Operational state data for a device alarm";
                uses alarm-config;
    
                uses alarm-state;
              }  // container state
            }  // list alarm
          }  // container alarms
        }  // grouping alarms-top
    
        augment /oc-platform:components/oc-platform:component/oc-platform:state {
          description
            "Adds specific alarms related to a component.";
          leaf equipment-failure {
            type boolean;
            default "false";
            description
              "If true, the hardware indicates that the component's physical equipment
            has failed";
          }
    
          leaf equipment-mismatch {
            type boolean;
            default "false";
            description
              "If true, the hardware indicates that the component inserted into the
            affected component's physical location is of a different type than what
            is configured";
          }
        }
      }  // module openconfig-alarms
    