This submodule contains a collection of YANG definitions for managing Broadband Forum TR-252i3 clause 5.6 Spectrum related profi...
Version: 2022-05-23
submodule bbf-vdsl-upstream-power-back-off-profile-body { yang-version 1.1; belongs-to bbf-vdsl { prefix bbf-vdsl; } organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Ken Kerpez, ASSIA, Inc. Editor: Joey Boyd, Adtran PS Leader: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia WA Director: Joey Boyd, Adtran"; description "This submodule contains a collection of YANG definitions for managing Broadband Forum TR-252i3 clause 5.6 Spectrum related profiles; Upstream Power Back-Off (UPBO) Profile. Copyright (c) 2016-2022 Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-355a4; see the TR itself for full legal notices."; revision "2022-05-23" { description "Amendment 4. * Approval Date: 2022-05-23 * Publication Date: 2022-05-23."; reference "TR-355a4: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-4.pdf>"; } revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13 * Publication Date: 2020-10-13."; reference "TR-355a3: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-3.pdf>"; } revision "2019-10-21" { description "Amendment 2 Corrigendum 1. * Approval Date: 2019-10-21 * Publication Date: 2019-10-21."; reference "TR-355a2c1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-2.pdf>"; } revision "2019-06-11" { description "Amendment 2. * Approval Date: 2019-06-11 * Publication Date: 2019-06-11."; reference "TR-355a2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-2.pdf>"; } revision "2018-10-01" { description "Amendment 1. * Approval Date: 2018-10-01 * Publication Date: 2018-10-01."; reference "TR-355a1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-1.pdf>"; } revision "2017-11-27" { description "Corrigendum 2 (fixes to the previous revision). * Approval Date: see revision date above. * Publication Date: 2018-01-19."; reference "TR-355c2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Corrigendum-2.pdf>"; } revision "2016-07-18" { description "Initial revision. * Approval Date: see revision date above. * Publication Date: 2016-08-05."; reference "TR-355: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355.pdf>"; } grouping upstream-power-back-off-profile { description "This configures Upstream Power Back-Off (UPBO)."; leaf upbo-electrical-length { type uint16 { range "0..1280"; } units "0.1 dB"; default "0"; description "This parameter defines the electrical length expressed in dB at 1 MHz, kl0, configured by the Central Office Management Information Base (CO-MIB). The value ranges from 0 to 128 dB in steps of 0.1 dB."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (UPBOKL)"; } leaf upbo-force-electrical-length { type boolean; default "false"; description "This parameter is a flag that forces the VTU-R to use the electrical length of the Central Office Management Information Base (CO-MIB) (UPBOKL) to compute the Upstream Power Back-Off (UPBO). The value will be forced if the flag is set to true. Otherwise, if false the xDSL Transceiver Units (xTU) will determine the electrical length."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (UPBOKLF)"; } list upbopsd-pb { key "band"; description "This parameter defines the Upstream Power Back-Off (UPBO) reference Power Spectral Density (PSD) used to compute the upstream power back-off for each upstream band except US0. A UPBOPSD defined for each band will consist of two parameters [a, b]. Parameter a ranges from 40 dBm per Hz to 80.95 dBm per Hz in steps of 0.01 dBm per Hz; and parameter b ranges from 0 to 40.95 dBm per Hz in steps of 0.01 dBm perHz. The UPBO reference PSD at the frequency f expressed in MHz will be equal to a bvf. The set of parameter values a = 40 dBm per Hz, b = 0 dBm per Hz is a special configuration to disable UPBO in the respective upstream band."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (UPBOPSD-pb)"; leaf band { type uint8 { range "0..4"; } description "Identifies the upstream band, e.g., a value of 1 denotes US1."; } leaf upbopsd-a { type uint16 { range "4000..8095"; } units "0.01 dBm per Hz"; default "4000"; description "Upstream Power Back-Off (UPBO) parameter A."; } leaf upbopsd-b { type uint16 { range "0..4095"; } units "0.01 dBm per Hz"; default "0"; description "Upstream Power Back-Off (UPBO) parameter B."; } } // list upbopsd-pb list upbo-reference-electrical-length-pb { key "band"; description "This parameter defines the Upstream Power Back-Off (UPBO) reference electrical length used to compute the upstream power back-off for each upstream band except US0, for the optional Equalized Far-End Crosstalk (FEXT) UPBO method. The value ranges from 1.8 to 63.5 dB in steps of 0.1 dB. The use of the special value (enum equalized-fext-upbo-disabled) is described in clause 7.2.1.3.2 of ITU-T G.993.2 for kl0_REF=0."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (UPBOKLREF-pb); ITU-T G.993.2 clause 7.2.1.3.2"; leaf band { type uint8 { range "0..4"; } description "Identifies the upstream band, e.g., a value of 1 denotes US1."; } leaf upbo-reference-electrical-length { type union { type uint16 { range "18..635"; } type enumeration { enum "equalized-fext-upbo-disabled" { value 0; description "Indicates that equalized Far-End Crosstalk (FEXT) Upstream Power Back-Off (UPBO) is disabled."; } } } units "0.1 dB"; default "equalized-fext-upbo-disabled"; description "The Upstream Power Back-Off (UPBO) reference electrical length."; } } // list upbo-reference-electrical-length-pb leaf aele-mode { type enumeration { enum "0" { value 0; description "kl0[band] = ELE-M0 VTU-O kl0 estimate."; } enum "1" { value 1; description "kl0[band] = ELEDS [dB], with band in the set {upbo_bands}."; } enum "2" { value 2; description "kl0[band] = ELE[band] [dB], with band in the set {upbo_bands}."; } enum "3" { value 3; description "kl0[band] = MIN(ELEUS, ELEDS) [dB], with band in the set {upbo_bands}."; } } default "0"; description "This parameter defines the Upstream Power Back-Off (UPBO) electrical length estimation mode to be used in the alternative electrical length estimation method (ELE-M1). The value of this parameter is 0, 1, 2 or 3. The default is enum 0, kl0[band] = ELE-M0 VTU-O kl0 estimate."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (AELE-MODE); ITU-T G.993.2 clause 7.2.1.3.2.2 (ELE-M1)"; } leaf upbo-elmt { type uint8 { range "0..15"; } units "percent"; default "0"; description "This parameter defines the Upstream Power Back-Off (UPBO) electrical length minimum threshold percentile in percent used in the alternative electrical length estimation method (ELE-M1). It is set by network management via the Central Office Management Information Base (CO-MIB). The parameter ranges from 0 to 15 percent in steps of 1 percent. This value is communicated to the VDSL Transceiver Unit - Remote side (VTU-R) in accordance with ITU-T G.994.1 at start-up."; reference "ITU-T G.997.1 clause 7.3.1.2.14 (UPBOELMT); ITU-T G.993.2 clause 7.2.1.3.2.2 (ELE-M1)"; } } // grouping upstream-power-back-off-profile } // submodule bbf-vdsl-upstream-power-back-off-profile-body
© 2023 YumaWorks, Inc. All rights reserved.