bbf-vdsl-re-initialization-policy-profile-body

This submodule contains a collection of YANG definitions for managing Broadband Forum TR-252i3 clause 5.7 DSL Quality Management...

  • Version: 2020-10-13

    bbf-vdsl-re-initialization-policy-profile-body@2020-10-13


    
      submodule bbf-vdsl-re-initialization-policy-profile-body {
    
        yang-version 1.1;
    
        belongs-to bbf-vdsl {
            prefix bbf-vdsl;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, ADTRAN
    
         PS Leader:   Sowrirajan Padmanabhan, Nokia
    
         PS Leader:   Joey Boyd, ADTRAN
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, ADTRAN";
    
        description
          "This submodule contains a collection of YANG definitions for
         managing Broadband Forum TR-252i3 clause 5.7 DSL Quality
         Management related profiles; Re-initialization Policy Profile.
    
         Copyright (c) 2016-2020 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a3; see
         the TR itself for full legal notices.";
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2019-10-21" {
          description
            "Amendment 2 Corrigendum 1.
           * Approval Date:    2019-10-21
           * Publication Date: 2019-10-21.";
          reference
            "TR-355a2c1: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
           * Approval Date:    2019-06-11
           * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
           * Approval Date:    2018-10-01
           * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
        revision "2017-11-27" {
          description
            "Corrigendum 2 (fixes to the previous revision).
           * Approval Date:    see revision date above.
           * Publication Date: 2018-01-19.";
          reference
            "TR-355c2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Corrigendum-2.pdf>";
    
        }
    
        revision "2016-07-18" {
          description
            "Initial revision.
           * Approval Date:    see revision date above.
           * Publication Date: 2016-08-05.";
          reference
            "TR-355: YANG Modules for FTTdp Management
            	<https://www.broadband-forum.org/technical/download/
            		 TR-355.pdf>";
    
        }
    
    
        grouping re-initialization-policy-profile {
          description
            "Configuration of the re-initialization policy allows control
           of re-initialization based on error performance thresholds
           of the line.";
          leaf ripolicy {
            type uint8 {
              range "0..1";
            }
            default "0";
            description
              "The re-initialization policy (RIPOLICY) parameter indicates w
             which policy will be applied to determine the triggers for
             re-initialization in the direction of transmisson (see clause
             12.1.4 of [ITU-T G.993.2] and clauses 7.3.1.1.13 and
             7.2.1.1.5 of [ITU-T G.997.1]).
             If RIPOLICY=1 is configured and it is detected during
             ITU-T G.993.2 initialization that RIPOLICY=1 is not
             supported in the direction of transmission by either of
             the xDSL Transceiver Units (xTU), the xTUs will fallback to
             RIPOLICY=0. The valid values for RIPOLICY are 0 and 1.
             The default is RIPOLICY=0.";
            reference
              "ITU-T G.997.1 clause 7.3.1.1.12.1 Downstream
              re-initialization policy selection (RIPOLICYds) and
              clause 7.3.1.1.12.2 Upstream re-initialization policy
              selection (RIPOLICYus)";
    
          }
    
          leaf reinit-time-threshold {
            type uint8 {
              range "5..31";
            }
            default "10";
            description
              "The parameter REINIT_TIME_THRESHOLD defines the
             threshold for re-initialization based on Severely Errored
             Seconds (SES), to be used by the xDSL Transceiver Unit (xTU)
             receiver when re-initialization policy 1 is used in the
             direction of transmission (see clause 12.1.4 of
             [ITU-T G.993.2]). The valid range is from 5 to 31.";
            reference
              "ITU-T G.997.1 clause 7.3.1.1.13.1 Downstream
              REINIT_TIME_THRESHOLDds and clause 7.3.1.1.13.2 Upstream
              REINIT_TIME_THRESHOLDus";
    
          }
        }  // grouping re-initialization-policy-profile
      }  // submodule bbf-vdsl-re-initialization-policy-profile-body
    

© 2023 YumaWorks, Inc. All rights reserved.