per-sub-carrier-int32-tuple |
binary |
A binary type where each group of 8 octets represents a tuple.
A tuple consists of two 4-octet groups and represents data
belonging to a sub-carrier. The first tuple represents
sub-carrier group 0 and the last tuple represents sub-carrier
group (length/8 - 1). In each 4-octet group in the tuple,
the most significant byte is loaded first. The order of the
tuples is determined by the node to which this type is
associated. |
per-sub-carrier-int32-tuple |
binary |
A binary type where each group of 8 octets represents a tuple.
A tuple consists of two 4-octet groups and represents data
belonging to a sub-carrier. The first tuple represents
sub-carrier group 0 and the last tuple represents sub-carrier
group (length/8 - 1). In each 4-octet group in the
tuple, the most significant byte is loaded first. The order of
the tuples is determined by the node to which this type is
associated. |
per-sub-carrier-uint16 |
binary |
A binary type where each pair of octets represents data
belonging to a sub-carrier group. The first pair represents
sub-carrier group 0 and the last represents sub-carrier
group (length/2 - 1). |
per-sub-carrier-uint16 |
binary |
A binary type where each pair of octets represents data
belonging to a sub-carrier group. The first pair represents
sub-carrier group 0 and the last represents sub-carrier
group (length/2 - 1). |
per-sub-carrier-uint8 |
binary |
A binary type where each octet represents data belonging to
a sub-carrier group. The first octet represents sub-carrier
group 0 and the last octet represents the sub-carrier
group (length - 1). |
per-sub-carrier-uint8 |
binary |
A binary type where each octet represents data belonging to
a sub-carrier group. The first octet represents sub-carrier
group 0 and the last octet represents the sub-carrier
group (length - 1). |
pmd-function |
enumeration |
The Central Office (CO) Single Ended Line Test Physical Medium
Dependent (SELT-PMD) function. |
pmd-function |
enumeration |
The Central Office (CO) Single Ended Line Test Physical Medium
Dependent (SELT-PMD) function. |
pmd-profile-ref |
leafref |
Used to reference a Physical Medium Dependent (PMD) profile. |
pmd-profile-ref |
leafref |
Used to reference a Physical Medium Dependent (PMD) profile. |
pmd-result |
enumeration |
The overall results of the SELT PMD measurement. |
pmd-result |
enumeration |
The overall results of the SELT PMD measurement. |
qln-measurement-duration |
uint8 |
This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Quiet Line Noise (QLN) measurement, between
the time of the start command written by the Single Ended Line
Test Physical Medium Dependent Management Entity (SELT-PMD-ME),
and the time the result is available for read operation by
SELT-PMD-ME.
NOTE - The above duration includes internal pre-processing and
post-processing.
It is configurable between 1 second and 240 seconds, in steps
of 1 second. |
qln-measurement-duration |
uint8 |
This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Quiet Line Noise (QLN) measurement, between
the time of the start command written by the Single Ended Line
Test Physical Medium Dependent Management Entity (SELT-PMD-ME),
and the time the result is available for read operation by
SELT-PMD-ME.
NOTE - The above duration includes internal pre-processing and
post-processing.
It is configurable between 1 second and 240 seconds, in steps
of 1 second. |
sub-carrier-index |
uint16 |
Identifies a sub-carrier. |
sub-carrier-index |
uint16 |
Identifies a sub-carrier. |
uer-measurement-duration |
uint8 |
This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Uncalibrated Echo Response (UER) measurement,
between the time of the start command written by the Single
Ended Line Test Physical Medium Dependent Management Entity
(SELT-PMD-ME), and the time the result is available for read
operation by SELT-PMD-ME.
NOTE - The above duration includes internal pre-processing and
post-processing.
It is configurable between 5 seconds and 240 seconds, in steps
of 1 second. |
uer-measurement-duration |
uint8 |
This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Uncalibrated Echo Response (UER) measurement,
between the time of the start command written by the
Single Ended Line Test Physical Medium Dependent Management
Entity (SELT-PMD-ME), and the time the result is available for
read operation by SELT-PMD-ME.
NOTE - The above duration includes internal pre-processing and
post-processing.
It is configurable between 5 seconds and 240 seconds, in steps
of 1 second. |