co-cpe-measurement-parameters |
uncalibrated-echo-response uncalibrated-echo-response-variance quiet-line-noise |
Defines the measurement parameters common between the Central
Office (CO) Single Ended Line Test Physical Medium Dependent
(SELT-PMD) and Customer Premises Equipment (CPE) SELT-PMD. |
co-cpe-measurement-parameters |
uncalibrated-echo-response uncalibrated-echo-response-variance quiet-line-noise |
Defines the measurement parameters common between the Central
Office (CO) Single Ended Line Test Physical Medium Dependent
(SELT-PMD) and Customer Premises Equipment (CPE) SELT-PMD. |
co-cpe-parameters |
uer-measurement-duration qln-measurement-duration |
Parameters to define the configuration common between the
Central Office (CO) CO Single Ended Line Test Physical Medium
Dependent (SELT-PMD) and Customer Premises Equipment (CPE)
SELT-PMD. |
co-cpe-parameters |
uer-measurement-duration qln-measurement-duration |
Parameters to define the configuration common between the
Central Office (CO) CO Single Ended Line Test Physical Medium
Dependent (SELT-PMD) and Customer Premises Equipment (CPE)
SELT-PMD. |
downstream-upstream-derived-parameters |
capacity-estimate |
Derived parameters that are common between the downstream and
upstream directions. |
downstream-upstream-derived-parameters |
capacity-estimate |
Derived parameters that are common between the downstream and
upstream directions. |
downstream-upstream-parameters |
capacity-estimate-signal-psd capacity-estimate-noise-psd capacity-estimate-target-noise-margin |
Parameters to define the configuration common between the
downstream and upstream directions. |
downstream-upstream-parameters |
capacity-estimate-signal-psd capacity-estimate-noise-psd capacity-estimate-target-noise-margin |
Parameters to define the configuration common between the
downstream and upstream directions. |
pmd-control |
pmd-control request-pmd-function-c |
Physical Medium Dependent (PMD) control configuration. |
pmd-control |
pmd-control request-pmd-function-c |
Physical Medium Dependent (PMD) control configuration. |
pmd-measurement-parameters |
c r |
Defines the Single Ended Line Test Physical Medium Dependent
(SELT-PMD) measurement parameters. |
pmd-measurement-parameters |
c r |
Defines the Single Ended Line Test Physical Medium Dependent
(SELT-PMD) measurement parameters. |
pmd-profile |
c r |
Defines the parameters contained in a Physical Medium Dependent
(PMD) profile. |
pmd-profile |
c r |
Defines the parameters contained in a Physical Medium Dependent
(PMD) profile. |
pmd-status |
selt-status-c uer-results-c qln-results-c |
Status parameters for the Physical Medium Dependent (PMD)
object. |
pmd-status |
selt-status-c uer-results-c qln-results-c |
Status parameters for the Physical Medium Dependent (PMD)
object. |
processing-derived-parameters |
loop-termination-indicator loop-length loop-topology attenuation-characteristics missing-micro-filter downstream upstream |
Defines the Single Ended Line Test Processing (SELT-P) derived
parameters. |
processing-derived-parameters |
loop-termination-indicator loop-length loop-topology attenuation-characteristics missing-micro-filter downstream upstream |
Defines the Single Ended Line Test Processing (SELT-P) derived
parameters. |
processing-profile |
capacity-estimate-calculation-enabling downstream upstream |
Defines the parameters contained in a processing profile. |
processing-profile |
capacity-estimate-calculation-enabling downstream upstream |
Defines the parameters contained in a processing profile. |
selt-pmd-control |
uer-measurement-enable-c qln-measurement-enable-c |
Defines the parameters contained in the PMD control object. |
selt-pmd-control |
uer-measurement-enable-c qln-measurement-enable-c |
Defines the parameters contained in the PMD control object. |