This submodule contains a collection of YANG definitions for Metallic Line Test Physical Medium Dependent (MELT-PMD) reporting p...
Version: 2022-05-23
submodule bbf-melt-pmd-reporting-parameter-body { yang-version 1.1; belongs-to bbf-melt { prefix bbf-melt; } include bbf-melt-pmd-measurement-parameter-body; include bbf-melt-base; organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Ken Kerpez, ASSIA, Inc. Editor: Joey Boyd, Adtran PS Leader: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia WA Director: Joey Boyd, Adtran"; description "This submodule contains a collection of YANG definitions for Metallic Line Test Physical Medium Dependent (MELT-PMD) reporting parameters. Copyright (c) 2016-2022 Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-355a4; see the TR itself for full legal notices."; revision "2022-05-23" { description "Amendment 4. * Approval Date: 2022-05-23 * Publication Date: 2022-05-23."; reference "TR-355a4: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-4.pdf>"; } revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13 * Publication Date: 2020-10-13."; reference "TR-355a3: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-3.pdf>"; } revision "2019-06-11" { description "Amendment 2. * Approval Date: 2019-06-11 * Publication Date: 2019-06-11."; reference "TR-355a2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-2.pdf>"; } revision "2018-10-01" { description "Amendment 1. * Approval Date: 2018-10-01 * Publication Date: 2018-10-01."; reference "TR-355a1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-1.pdf>"; } revision "2016-07-18" { description "Initial revision. * Approval Date: see revision date above. * Publication Date: 2016-08-05."; reference "TR-355: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355.pdf>"; } typedef melt-pmd-reporting-parameter { type enumeration { enum "measurement-frequency" { value 0; description "This parameter is the measurement frequency for a 3-element capacitance measurement, if performed with a sinewave signal, or a for 3-element complex admittance measurement. The range of valid values is from 10 to 1000 Hz with a granularity of 1 Hz."; reference "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)"; } enum "foreign-voltage-input-impedance" { value 1; description "This parameter reports the nominal input impedance of the measuring instrument during foreign voltage tests. The range of valid values is from 0 to 10 megaohms with a granularity of 1 ohm."; reference "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)"; } enum "loop-complex-admittance-measurement-voltage" { value 2; description "This parameter is the peak amplitude of the differential sinewave used by the measurement of the loop complex admittance with a high voltage metallic test. The range of valid values is from 0 to 150 volts and it shall be represented in linear format with a granularity of 0.1 volts."; reference "ITU-T G.996.2 clauses E.1.1.7 and E.2.2.3 (MELT-HCA-V)"; } } description "An enumerated list of MELT PMD reporting parameters."; } grouping pmd-reporting-parameters { description "Defines the Metallic Line Test Physical Medium Dependent (MELT-PMD) reporting parameters."; leaf measurement-frequency { type uint16 { range "10..1000"; } units "Hz"; description "This parameter is the measurement frequency for a 3-element capacitance measurement, if performed with a sinewave signal, or a for 3-element complex admittance measurement. The range of valid values is from 10 to 1000 Hz with a granularity of 1 Hz."; reference "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)"; } leaf foreign-voltage-input-impedance { type uint32 { range "0..10000000"; } units "ohms"; description "This parameter reports the nominal input impedance of the measuring instrument during foreign voltage tests. The range of valid values is from 0 to 10 megaohms with a granularity of 1 ohm."; reference "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)"; } leaf loop-complex-admittance-measurement-voltage { type measurement-voltage; description "This parameter is the peak amplitude of the differential sinewave used by the measurement of the loop complex admittance with a high voltage metallic test. The range of valid values is from 0 to 150 volts and it shall be represented in linear format with a granularity of 0.1 volts."; reference "ITU-T G.996.2 clauses E.1.1.7 and E.2.2.3 (MELT-HCA-V)"; } leaf unreliability-indicator { if-feature bbf-melt:melt-pmd-reporting-parameter-reliability; type bits { bit measurement-frequency { position 0; description "This parameter is the measurement frequency for a 3-element capacitance measurement, if performed with a sinewave signal, or a for 3-element complex admittance measurement. The range of valid values is from 10 to 1000 Hz with a granularity of 1 Hz."; reference "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)"; } bit foreign-voltage-input-impedance { position 1; description "This parameter reports the nominal input impedance of the measuring instrument during foreign voltage tests. The range of valid values is from 0 to 10 megaohms with a granularity of 1 ohm."; reference "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)"; } bit loop-complex-admittance-measurement-voltage { position 2; description "This parameter is the peak amplitude of the differential sinewave used by the measurement of the loop complex admittance with a high voltage metallic test. The range of valid values is from 0 to 150 volts and it shall be represented in linear format with a granularity of 0.1 volts."; reference "ITU-T G.996.2 clauses E.1.1.7 and E.2.2.3 (MELT-HCA-V)"; } } description "The unreliability indicator provides the set of parameters whose data can be considered to be unreliable. Possible reasons that the data is unreliable: - The measurement may not have been able to run, possibly due to external conditions. - The result is not reliable as the accuracy may be degraded due to external conditions."; reference "ITU-T G.996.2 clause E.2.2.4 (Reliability indicator)"; } container melt-pmd-reporting-vendor-specific-status { if-feature bbf-melt:melt-pmd-reporting-parameter-reliability; description "Vendor specific status associated with each MELT reporting test."; list status { key "parameter"; description "A list of per parameter test status."; leaf parameter { type melt-pmd-reporting-parameter; description "The MELT PMD reporting parameter."; } leaf message { type string; description "Vendor specific status message for each of the MELT PMD reporting parameters."; } } // list status } // container melt-pmd-reporting-vendor-specific-status } // grouping pmd-reporting-parameters } // submodule bbf-melt-pmd-reporting-parameter-body
© 2023 YumaWorks, Inc. All rights reserved.