bbf-melt-pmd-reporting-parameter-body

This submodule contains a collection of YANG definitions for Metallic Line Test Physical Medium Dependent (MELT-PMD) reporting p...

  • Version: 2020-10-13

    bbf-melt-pmd-reporting-parameter-body@2020-10-13


    
      submodule bbf-melt-pmd-reporting-parameter-body {
    
        yang-version 1.1;
    
        belongs-to bbf-melt {
            prefix bbf-melt;
        }
    
        include bbf-melt-pmd-measurement-parameter-body;
        include bbf-melt-base;
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
    Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
    should be directed to <mailto:help@broadband-forum.org>.
    
    Editor:      Ken Kerpez, ASSIA, Inc.
    
    Editor:      Joey Boyd, ADTRAN
    
    PS Leader:   Sowrirajan Padmanabhan, Nokia
    
    PS Leader:   Joey Boyd, ADTRAN
    
    WA Director: Sven Ooghe, Nokia
    
    WA Director: Joey Boyd, ADTRAN";
    
        description
          "This submodule contains a collection of YANG definitions for
    Metallic Line Test Physical Medium Dependent (MELT-PMD) reporting
    parameters.
    
    Copyright (c) 2016-2020 Broadband Forum
    
    Redistribution and use in source and binary forms, with or
    without modification, are permitted provided that the following
    conditions are met:
    
    1. Redistributions of source code must retain the above copyright
       notice, this list of conditions and the following disclaimer.
    
    2. Redistributions in binary form must reproduce the above
       copyright notice, this list of conditions and the following
       disclaimer in the documentation and/or other materials
       provided with the distribution.
    
    3. Neither the name of the copyright holder nor the names of its
       contributors may be used to endorse or promote products
       derived from this software without specific prior written
       permission.
    
    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
    CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
    INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
    MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
    DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
    CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
    SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
    NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
    LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
    CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
    STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
    ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
    ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
    The above license is used as a license under copyright only.
    Please reference the Forum IPR Policy for patent licensing terms
    <https://www.broadband-forum.org/ipr-policy>.
    
    Any moral rights which are necessary to exercise under the above
    license grant are also deemed granted under this license.
    
    This version of this YANG module is part of TR-355a3; see
    the TR itself for full legal notices.";
    
        revision "2020-10-13" {
          description
            "Amendment 3.
    * Approval Date:    2020-10-13
    * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2019-06-17" {
          description "Changes for amendment 3.";
          reference
            "TBD";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
    * Approval Date:    2019-06-11
    * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
    * Approval Date:    2018-10-01
    * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
        revision "2016-07-18" {
          description
            "Initial revision.
    * Approval Date:    see revision date above.
    * Publication Date: 2016-08-05.";
          reference
            "TR-355: YANG Modules for FTTdp Management
            	<https://www.broadband-forum.org/technical/download/
            		 TR-355.pdf>";
    
        }
    
    
        typedef melt-pmd-reporting-parameter {
          type enumeration {
            enum "measurement-frequency" {
              value 0;
              description
                "This parameter is the measurement frequency for a
    3-element capacitance measurement, if performed with a
    sinewave signal, or a for 3-element complex admittance
    measurement. The range of valid values is from 10 to 1000
    Hz with a granularity of 1 Hz.";
              reference
                "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)";
    
            }
            enum
              "foreign-voltage-input-impedance" {
              value 1;
              description
                "This parameter reports the nominal input impedance of the
    measuring instrument during foreign voltage tests. The
    range of valid values is from 0 to 10 Mohm with a
    granularity of 1 ohm.";
              reference
                "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)";
    
            }
            enum
              "loop-complex-admittance-measurement-voltage" {
              value 2;
              description
                "This parameter is the peak amplitude of the differential
    sinewave used by the measurement of the loop complex
    admittance with a high voltage metallic test (see
    clause E.1.1.7). The range of valid values is from 0 to
    150 V and it shall be represented in linear format with a
    granularity of 0.1 V.";
              reference
                "ITU-T G.996.2 clause E.2.2.3 (MELT-HCA-V)";
    
            }
          }
          description
            "An enumerated list of MELT PMD reporting parameters.";
        }
    
        grouping pmd-reporting-parameters {
          description
            "Defines the Metallic Line Test Physical Medium Dependent
    (MELT-PMD) reporting parameters.";
          leaf measurement-frequency {
            type uint16 {
              range "10..1000";
            }
            units "1 Hz";
            description
              "This parameter is the measurement frequency for a 3-element
    capacitance measurement, if performed with a sinewave
    signal, or a for 3-element complex admittance measurement.
    The range of valid values is from 10 to 1000 Hz with a
    granularity of 1 Hz.";
            reference
              "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)";
    
          }
    
          leaf foreign-voltage-input-impedance {
            type uint32 {
              range "0..10000000";
            }
            units "1 ohm";
            description
              "This parameter reports the nominal input impedance of the
    measuring instrument during foreign voltage tests. The range
    of valid values is from 0 to 10 Mohm with a granularity of
    1 ohm.";
            reference
              "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)";
    
          }
    
          leaf loop-complex-admittance-measurement-voltage {
            type measurement-voltage;
            description
              "This parameter is the peak amplitude of the differential
    sinewave used by the measurement of the loop complex
    admittance with a high voltage metallic test (see
    clause E.1.1.7). The range of valid values is from 0 to
    150 V and it shall be represented in linear format with a
    granularity of 0.1 V.";
            reference
              "ITU-T G.996.2 clause E.2.2.3 (MELT-HCA-V)";
    
          }
    
          leaf unreliability-indicator {
            if-feature bbf-melt:melt-pmd-reporting-parameter-reliability;
            type bits {
              bit measurement-frequency {
                position 0;
                description
                  "This parameter is the measurement frequency for a
    3-element capacitance measurement, if performed with a
    sinewave signal, or a for 3-element complex admittance
    measurement. The range of valid values is from 10 to 1000
    Hz with a granularity of 1 Hz.";
                reference
                  "ITU-T G.996.2 clause E.2.2.1 (MELT-MFREQ)";
    
              }
              bit
                foreign-voltage-input-impedance {
                position 1;
                description
                  "This parameter reports the nominal input impedance of the
    measuring instrument during foreign voltage tests. The
    range of valid values is from 0 to 10 Mohm with a
    granularity of 1 ohm.";
                reference
                  "ITU-T G.996.2 clause E.2.2.2 (MELT-IMP-V)";
    
              }
              bit
                loop-complex-admittance-measurement-voltage {
                position 2;
                description
                  "This parameter is the peak amplitude of the differential
    sinewave used by the measurement of the loop complex
    admittance with a high voltage metallic test (see
    clause E.1.1.7). The range of valid values is from 0 to
    150 V and it shall be represented in linear format with a
    granularity of 0.1 V.";
                reference
                  "ITU-T G.996.2 clause E.2.2.3 (MELT-HCA-V)";
    
              }
            }
            description
              "The unreliability indicator provides the set of parameters
    whose data can be considered to be unreliable.
    
    Possible reasons that the data is unreliable:
      - The measurement may not have been able to run, possibly
        due to external conditions.
      - The result is not reliable as the accuracy may be
        degraded due to external conditions.";
            reference
              "ITU-T G.996.2 clause E.2.2.4 (Reliability indicator)";
    
          }
    
          container melt-pmd-reporting-vendor-specific-status {
            if-feature bbf-melt:melt-pmd-reporting-parameter-reliability;
            description
              "Vendor specific status associated with each MELT
    reporting test.";
            list status {
              key "parameter";
              description
                "A list of per parameter test status.";
              leaf parameter {
                type melt-pmd-reporting-parameter;
                description
                  "The MELT PMD reporting parameter.";
              }
    
              leaf message {
                type string;
                description
                  "Vendor specific status message for each of the
    MELT PMD reporting parameters.";
              }
            }  // list status
          }  // container melt-pmd-reporting-vendor-specific-status
        }  // grouping pmd-reporting-parameters
      }  // submodule bbf-melt-pmd-reporting-parameter-body
    