This submodule contains a collection of YANG definitions for managing the Physical Medium Dependent (PMD) control object. Copyr...
Version: 2020-10-13
submodule bbf-melt-pmd-control-body { yang-version 1.1; belongs-to bbf-melt { prefix bbf-melt; } organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Ken Kerpez, ASSIA, Inc. Editor: Joey Boyd, ADTRAN PS Leader: Sowrirajan Padmanabhan, Nokia PS Leader: Joey Boyd, ADTRAN WA Director: Sven Ooghe, Nokia WA Director: Joey Boyd, ADTRAN"; description "This submodule contains a collection of YANG definitions for managing the Physical Medium Dependent (PMD) control object. Copyright (c) 2016-2020 Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-355a3; see the TR itself for full legal notices."; revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13 * Publication Date: 2020-10-13."; reference "TR-355a3: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-3.pdf>"; } revision "2019-06-11" { description "Amendment 2. * Approval Date: 2019-06-11 * Publication Date: 2019-06-11."; reference "TR-355a2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-2.pdf>"; } revision "2018-10-01" { description "Amendment 1. * Approval Date: 2018-10-01 * Publication Date: 2018-10-01."; reference "TR-355a1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-1.pdf>"; } revision "2016-07-18" { description "Initial revision. * Approval Date: see revision date above. * Publication Date: 2016-08-05."; reference "TR-355: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355.pdf>"; } typedef pmd-function { type enumeration { enum "measurement" { value 1; description "Triggers the Metallic Line Test Physical Medium Dependent (MELT-PMD) to start the test or tests specified by the measurement class (MELT-MCLASS)."; } enum "pair-identification-tone-generation" { value 2; description "Triggers the Metallic Line Test Physical Medium Dependent (MELT-PMD) to start a Pair Identification Tone (PIT) generation."; } } description "The MELT PMD function."; } grouping melt-pmd-control { description "Defines the parameters contained in the Physical Medium Dependent (PMD) control object."; choice pmd-functions { default "all-functions-disable"; status deprecated; description "Options for enabling/disabling Physical Medium Dependent (PMD) functions."; case all-functions-disable { status deprecated; leaf all-functions-disable { type empty; status deprecated; description "Disable all Physical Medium Dependent (PMD) control functions."; } } // case all-functions-disable case measurement-enable-c { status deprecated; leaf measurement-enable-c { type empty; status deprecated; description "Enables the test or tests specified by the measurement class (MELT-MCLASS)."; } } // case measurement-enable-c case pair-identification-tone-generation-enable { status deprecated; leaf pair-identification-tone-generation-enable { type empty; status deprecated; description "Enables pair identification tone generation."; } } // case pair-identification-tone-generation-enable } // choice pmd-functions } // grouping melt-pmd-control grouping pmd-control { description "Physical Medium Dependent (PMD) control functions."; leaf pmd-control { type enumeration { enum "disable" { value 0; description "The Metallic Line Test Physical Medium Dependent (MELT-PMD) functionality is not configured for a measurement or Pair Identification Tone (PIT) generation."; } enum "enable" { value 1; description "The Metallic Line Test Physical Medium Dependent (MELT-PMD) functionality is configured for a measurement or Pair Identification Tone (PIT) generation."; } } default "disable"; description "This parameter configures the Metallic Line Test Physical Medium Dependent (MELT-PMD) for a MELT measurement or Pair Identification Tone (PIT) generation."; } action request-pmd-function-c { description "Requests to disable or enable PMD functions."; input { leaf pmd-function { type union { type enumeration { enum "abort" { value 0; description "Triggers the Metallic Line Test Physical Medium Dependent (MELT-PMD) to abort any ongoing measurement or Pair Identification Tone (PIT) generation."; } } type pmd-function; } description "A measurement or Pair Identification Tone (PIT) generation is by default not triggered. A measurement or PIT generation is triggered when the action is sent with the appropriate function specified. One or more measurements or PIT generations may be triggered while the Metallic Line Test Physical Medium Dependent (MELT-PMD) is configured 'enable', possibly with different MELT PMD configuration parameters. If the triggered measurement or PIT generation cannot be executed, then the Access Node/Distribution Point Unit (AN/DPU) Management Entitiy (ME) rejects this action and the MELT PMD status remains 'inactive'."; } } } // rpc request-pmd-function-c } // grouping pmd-control } // submodule bbf-melt-pmd-control-body
© 2023 YumaWorks, Inc. All rights reserved.