bbf-hardware-rpf-dpu

This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on management of Reverse P...

  • Version: 2022-05-23

    bbf-hardware-rpf-dpu@2022-05-23


    
      module bbf-hardware-rpf-dpu {
    
        yang-version 1.1;
    
        namespace
          "urn:bbf:yang:bbf-hardware-rpf-dpu";
    
        prefix bbf-hw-rpf-dpu;
    
        import bbf-hardware-types {
          prefix bbf-hwt;
        }
        import bbf-yang-types {
          prefix bbf-yang;
        }
        import ietf-hardware {
          prefix hw;
        }
        import ietf-inet-types {
          prefix inet;
        }
        import ietf-yang-types {
          prefix yang;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, Adtran
    
         PS Leader:   Joey Boyd, Adtran
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, Adtran";
    
        description
          "This module contains a collection of YANG definitions for
         supporting the Broadband Forum requirements on management of
         Reverse Power Feeding (RPF) as defined in ITU G.997.2 Annex A and
         BBF TR-159. As such, this module is specific to access network
         equipment (e.g., BBF-specified Access Nodes and FTTdp DPUs).
    
         Copyright (c) 2016-2022 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a4; see
         the TR itself for full legal notices.";
    
        revision "2022-05-23" {
          description
            "Amendment 4.
           * Approval Date:    2022-05-23
           * Publication Date: 2022-05-23.";
          reference
            "TR-355a4: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-4.pdf>";
    
        }
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
           * Approval Date:    2019-06-11
           * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
           * Approval Date:    2018-10-01
           * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
    
        feature performance-24hr {
          description
            "Indicates that collection of 24 hour performance intervals
           is supported.";
        }
    
        typedef performance-15min-interval {
          type uint8 {
            range "0..96";
          }
          description
            "Defines the range of 15 minute intervals.";
        }
    
        typedef performance-15min-history-interval {
          type performance-15min-interval {
            range "1..96";
          }
          description
            "Defines the range of 15 minutes intervals and defines
           the position of the interval relative to the current interval
           where 1 is the most recent completed interval.";
        }
    
        typedef performance-24hr-interval {
          type uint8 {
            range "0..7";
          }
          description
            "Defines the range of 24 hour intervals.";
        }
    
        typedef performance-24hr-history-interval {
          type performance-24hr-interval {
            range "1..7";
          }
          description
            "Defines the range of 24 hour intervals and defines
           the position of the interval relative to the current interval
           where 1 is the most recent completed interval.";
        }
    
        typedef dpu-reconfiguration-state {
          type enumeration {
            enum "normal" {
              value 0;
              description
                "The line is in Normal mode.";
            }
            enum "bypass" {
              value 1;
              description
                "The line is in Bypass mode.";
            }
          }
          description
            "Reports the ReConfiguration State for the line. A state
           change alarm shall be raised indicating a change of the
           line's Reconfiguration State.";
          reference
            "ITU-T G.997.2 clauses A.7.2.1.2 and A.7.4.1.3 (DPU-RCS)";
    
        }
    
        typedef pse-rpf-state {
          type enumeration {
            enum "pse-ukn" {
              value 0;
              description
                "Shutdown with unknown reason as initial state.
                - when for the line the Power Extractor (PE) transitions
                  to 'start-up' after the PE detects loss of voltage,
                  and has not received a PSE-DGL or PSE-OHP
                  indication from the Power Source Equipment (PSE).";
            }
            enum "pse-dgl" {
              value 1;
              description
                "Shutdown with dying gasp (normal shutdown).
                - when for the line the Power Extractor (PE) transitions
                  to 'start-up' after the PE detects loss of voltage
                  and has received a PSE-DGL indication from the Power
                  Source Equipment (PSE).";
            }
            enum "pse-ohp" {
              value 2;
              description
                "Shutdown with dying gasp with off-hook phone.
                - when for the line the Power Extractor (PE) transitions
                  to 'start-up' after the PE detects loss of voltage
                  and has received a PSE-OHP indication from the Power
                  Source Equipment (PSE).";
            }
            enum "pse-pwr" {
              value 3;
              description
                "Powered with unknown Power Source Equipment (PSE) powering
               method.
                - when for the line the Power Extractor (PE) transitions
                  to 'normal-operations' and it is yet unknown whether the
                  PSE is battery powered or mains powered.";
            }
            enum "pse-bat" {
              value 4;
              description
                "Battery powered.
                - when for the line the Power Extractor (PE) transitions
                  to 'normal-operations' and the PE received an indication
                  that the Power Source Equipment (PSE) is trying to start
                  up the DPU while powered on battery;
                - when for the line the PE is in 'normal-operations' and
                  the PE receives a PSE-BAT indication from the PSE.";
            }
            enum "pse-acm" {
              value 5;
              description
                "Mains powered.
                - when for the line the Power Extractor (PE) transitions
                  to 'normal-operations' and the PE received an indication
                  that the Power Source Equipment (PSE) was trying to
                  start up the Distribution Point Unit (DPU) while powered
                  on mains;
                - when for the line the PE is in 'normal-operations' and
                  the PE receives a PSE-ACM or PSE-BBA indication from the
                  PSE.";
            }
          }
          description
            "Reports the reverse power feeding state of the Power Source
           Equipment (PSE).";
          reference
            "ITU-T G.997.2 clauses A.6.2.2 and A.7.4.2.2 (PSE-RPF);
            ETSI TS 101 548";
    
        }
    
        identity rpf-threshold-crossing-alert {
          description
            "Base identity for Reverse Power Feeding (RPF) threshold
           crossing alerts (TCA).
    
           This identity is abstract and is not be used for a
           threshold crossing alert.";
        }
    
        identity rpf-15min-threshold-crossing-alert {
          base rpf-threshold-crossing-alert;
          description
            "A threshold crossing alert associated with performance
           counters collected over the current 15 minute interval
           for Reverse Power Feeding (RPF).
    
           This identity is abstract and is not be used for a
           threshold crossing alert.";
        }
    
        identity rpf-24hr-threshold-crossing-alert {
          base rpf-threshold-crossing-alert;
          description
            "A threshold crossing alert associated with performance
           counters collected over the current 24 hour interval
           for Reverse Power Feeding (RPF).
    
           This identity is abstract and is not be used for a
           threshold crossing alert.";
        }
    
        identity dpu-15min-extracted-energy-tca {
          base rpf-15min-threshold-crossing-alert;
          description
            "The count of the Distribution Point Unit (DPU) extracted energy
           per line at U-O interface or at Power Supply Unit (PSU) input
           in the current 15 minute interval has exceeded the configured
           threshold.";
          reference
            "ITU-T G.997.2 clause A.7.3.4 (CURR/PREV_NE_15/24_EE)";
    
        }
    
        identity dpu-24hr-extracted-energy-tca {
          base rpf-24hr-threshold-crossing-alert;
          description
            "The count of the DPU extracted energy per line at U-O interface
           or at Power Supply Unit (PSU) input in the current 24 hour
           interval has exceeded the configured threshold.";
          reference
            "ITU-T G.997.2 clause A.7.3.4 (CURR/PREV_NE_15/24_EE)";
    
        }
    
        identity pse-15min-injected-energy-tca {
          base rpf-15min-threshold-crossing-alert;
          description
            "The count of the Power Source Equipment (PSE) injected energy
           per line in the current 15 minute interval has exceeded the
           configured threshold.";
          reference
            "ITU-T G.997.2 clause A.7.3.5 (CURR/PREV_FE_15/24_IE)";
    
        }
    
        identity pse-24hr-injected-energy-tca {
          base rpf-24hr-threshold-crossing-alert;
          description
            "The count of the Power Source Equipment (PSE) injected energy
           per line in the current 24 hour interval has exceeded the
           configured threshold.";
          reference
            "ITU-T G.997.2 clause A.7.3.5 (CURR/PREV_FE_15/24_IE)";
    
        }
    
        container rpf {
          description
            "System level configuration of Reverse Power Feeding.";
          container near-end-system {
            description
              "System configuration associated with the near-end.";
            leaf dying-gasp-udp-port {
              type inet:port-number;
              description
                "The UDP port number used for dying gasp messages.";
              reference
                "BBF TR-301i2 R-21.";
    
            }
          }  // container near-end-system
        }  // container rpf
    
        notification loss-of-power-dpu-shutdown {
          description
            "This notification is sent when the Distribution Point Unit
           (DPU) is about to shutdown because the Reverse Power Feeding
           (RPF) state of the last reverse power feeding line has entered
           the 'PSE-DGL' state. In case of an actual shutdown, this
           notification may not get transmitted.";
          leaf line {
            type leafref {
              path "/hw:hardware/hw:component/hw:name";
            }
            must
              "derived-from-or-self(/hw:hardware/hw:component
                [hw:name=current()]/hw:class,'bbf-hwt:fastdsl-tp')" {
              description
                "Only hardware components which are capable of
               Reverse Power Feeding (RPF) must be referenced.";
            }
            mandatory true;
            description
              "Reference to the line which was the last reverse power
             feeding line to enter the 'PSE-DGL' state.";
          }
    
          leaf line-id {
            type uint32 {
              range "1..4095";
            }
            mandatory true;
            description
              "A unique numeric identifier associated with the port.";
            reference
              "TR-301i2 Figure 8-1";
    
          }
    
          leaf rpf-state {
            type pse-rpf-state;
            mandatory true;
            description
              "Reports the reverse power feeding state of the Power Source
             Equipment (PSE).";
            reference
              "ITU-T G.997.2 clause A.7.4.2.2 (PSE-RPF)";
    
          }
        }  // notification loss-of-power-dpu-shutdown
      }  // module bbf-hardware-rpf-dpu
    