This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on management of Reverse P...
Version: 2022-05-23
module bbf-hardware-rpf-dpu { yang-version 1.1; namespace "urn:bbf:yang:bbf-hardware-rpf-dpu"; prefix bbf-hw-rpf-dpu; import bbf-hardware-types { prefix bbf-hwt; } import bbf-yang-types { prefix bbf-yang; } import ietf-hardware { prefix hw; } import ietf-inet-types { prefix inet; } import ietf-yang-types { prefix yang; } organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Ken Kerpez, ASSIA, Inc. Editor: Joey Boyd, Adtran PS Leader: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia WA Director: Joey Boyd, Adtran"; description "This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on management of Reverse Power Feeding (RPF) as defined in ITU G.997.2 Annex A and BBF TR-159. As such, this module is specific to access network equipment (e.g., BBF-specified Access Nodes and FTTdp DPUs). Copyright (c) 2016-2022 Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-355a4; see the TR itself for full legal notices."; revision "2022-05-23" { description "Amendment 4. * Approval Date: 2022-05-23 * Publication Date: 2022-05-23."; reference "TR-355a4: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-4.pdf>"; } revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13 * Publication Date: 2020-10-13."; reference "TR-355a3: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-3.pdf>"; } revision "2019-06-11" { description "Amendment 2. * Approval Date: 2019-06-11 * Publication Date: 2019-06-11."; reference "TR-355a2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-2.pdf>"; } revision "2018-10-01" { description "Amendment 1. * Approval Date: 2018-10-01 * Publication Date: 2018-10-01."; reference "TR-355a1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-1.pdf>"; } feature performance-24hr { description "Indicates that collection of 24 hour performance intervals is supported."; } typedef performance-15min-interval { type uint8 { range "0..96"; } description "Defines the range of 15 minute intervals."; } typedef performance-15min-history-interval { type performance-15min-interval { range "1..96"; } description "Defines the range of 15 minutes intervals and defines the position of the interval relative to the current interval where 1 is the most recent completed interval."; } typedef performance-24hr-interval { type uint8 { range "0..7"; } description "Defines the range of 24 hour intervals."; } typedef performance-24hr-history-interval { type performance-24hr-interval { range "1..7"; } description "Defines the range of 24 hour intervals and defines the position of the interval relative to the current interval where 1 is the most recent completed interval."; } typedef dpu-reconfiguration-state { type enumeration { enum "normal" { value 0; description "The line is in Normal mode."; } enum "bypass" { value 1; description "The line is in Bypass mode."; } } description "Reports the ReConfiguration State for the line. A state change alarm shall be raised indicating a change of the line's Reconfiguration State."; reference "ITU-T G.997.2 clauses A.7.2.1.2 and A.7.4.1.3 (DPU-RCS)"; } typedef pse-rpf-state { type enumeration { enum "pse-ukn" { value 0; description "Shutdown with unknown reason as initial state. - when for the line the Power Extractor (PE) transitions to 'start-up' after the PE detects loss of voltage, and has not received a PSE-DGL or PSE-OHP indication from the Power Source Equipment (PSE)."; } enum "pse-dgl" { value 1; description "Shutdown with dying gasp (normal shutdown). - when for the line the Power Extractor (PE) transitions to 'start-up' after the PE detects loss of voltage and has received a PSE-DGL indication from the Power Source Equipment (PSE)."; } enum "pse-ohp" { value 2; description "Shutdown with dying gasp with off-hook phone. - when for the line the Power Extractor (PE) transitions to 'start-up' after the PE detects loss of voltage and has received a PSE-OHP indication from the Power Source Equipment (PSE)."; } enum "pse-pwr" { value 3; description "Powered with unknown Power Source Equipment (PSE) powering method. - when for the line the Power Extractor (PE) transitions to 'normal-operations' and it is yet unknown whether the PSE is battery powered or mains powered."; } enum "pse-bat" { value 4; description "Battery powered. - when for the line the Power Extractor (PE) transitions to 'normal-operations' and the PE received an indication that the Power Source Equipment (PSE) is trying to start up the DPU while powered on battery; - when for the line the PE is in 'normal-operations' and the PE receives a PSE-BAT indication from the PSE."; } enum "pse-acm" { value 5; description "Mains powered. - when for the line the Power Extractor (PE) transitions to 'normal-operations' and the PE received an indication that the Power Source Equipment (PSE) was trying to start up the Distribution Point Unit (DPU) while powered on mains; - when for the line the PE is in 'normal-operations' and the PE receives a PSE-ACM or PSE-BBA indication from the PSE."; } } description "Reports the reverse power feeding state of the Power Source Equipment (PSE)."; reference "ITU-T G.997.2 clauses A.6.2.2 and A.7.4.2.2 (PSE-RPF); ETSI TS 101 548"; } identity rpf-threshold-crossing-alert { description "Base identity for Reverse Power Feeding (RPF) threshold crossing alerts (TCA). This identity is abstract and is not be used for a threshold crossing alert."; } identity rpf-15min-threshold-crossing-alert { base rpf-threshold-crossing-alert; description "A threshold crossing alert associated with performance counters collected over the current 15 minute interval for Reverse Power Feeding (RPF). This identity is abstract and is not be used for a threshold crossing alert."; } identity rpf-24hr-threshold-crossing-alert { base rpf-threshold-crossing-alert; description "A threshold crossing alert associated with performance counters collected over the current 24 hour interval for Reverse Power Feeding (RPF). This identity is abstract and is not be used for a threshold crossing alert."; } identity dpu-15min-extracted-energy-tca { base rpf-15min-threshold-crossing-alert; description "The count of the Distribution Point Unit (DPU) extracted energy per line at U-O interface or at Power Supply Unit (PSU) input in the current 15 minute interval has exceeded the configured threshold."; reference "ITU-T G.997.2 clause A.7.3.4 (CURR/PREV_NE_15/24_EE)"; } identity dpu-24hr-extracted-energy-tca { base rpf-24hr-threshold-crossing-alert; description "The count of the DPU extracted energy per line at U-O interface or at Power Supply Unit (PSU) input in the current 24 hour interval has exceeded the configured threshold."; reference "ITU-T G.997.2 clause A.7.3.4 (CURR/PREV_NE_15/24_EE)"; } identity pse-15min-injected-energy-tca { base rpf-15min-threshold-crossing-alert; description "The count of the Power Source Equipment (PSE) injected energy per line in the current 15 minute interval has exceeded the configured threshold."; reference "ITU-T G.997.2 clause A.7.3.5 (CURR/PREV_FE_15/24_IE)"; } identity pse-24hr-injected-energy-tca { base rpf-24hr-threshold-crossing-alert; description "The count of the Power Source Equipment (PSE) injected energy per line in the current 24 hour interval has exceeded the configured threshold."; reference "ITU-T G.997.2 clause A.7.3.5 (CURR/PREV_FE_15/24_IE)"; } container rpf { description "System level configuration of Reverse Power Feeding."; container near-end-system { description "System configuration associated with the near-end."; leaf dying-gasp-udp-port { type inet:port-number; description "The UDP port number used for dying gasp messages."; reference "BBF TR-301i2 R-21."; } } // container near-end-system } // container rpf notification loss-of-power-dpu-shutdown { description "This notification is sent when the Distribution Point Unit (DPU) is about to shutdown because the Reverse Power Feeding (RPF) state of the last reverse power feeding line has entered the 'PSE-DGL' state. In case of an actual shutdown, this notification may not get transmitted."; leaf line { type leafref { path "/hw:hardware/hw:component/hw:name"; } must "derived-from-or-self(/hw:hardware/hw:component [hw:name=current()]/hw:class,'bbf-hwt:fastdsl-tp')" { description "Only hardware components which are capable of Reverse Power Feeding (RPF) must be referenced."; } mandatory true; description "Reference to the line which was the last reverse power feeding line to enter the 'PSE-DGL' state."; } leaf line-id { type uint32 { range "1..4095"; } mandatory true; description "A unique numeric identifier associated with the port."; reference "TR-301i2 Figure 8-1"; } leaf rpf-state { type pse-rpf-state; mandatory true; description "Reports the reverse power feeding state of the Power Source Equipment (PSE)."; reference "ITU-T G.997.2 clause A.7.4.2.2 (PSE-RPF)"; } } // notification loss-of-power-dpu-shutdown } // module bbf-hardware-rpf-dpu
© 2023 YumaWorks, Inc. All rights reserved.