bbf-hardware-rpf-dpu-state

This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on management of Reverse P...

Grouping Objects Abstract
far-end-performance-counters pse-injected-energy Performance counters associated with the far-end.
far-end-performance-counters pse-injected-energy Performance counters associated with the far-end.
near-end-performance-counters dpu-extracted-energy Performance counters associated with the near-end.
near-end-performance-counters dpu-extracted-energy Performance counters associated with the near-end.
performance-15min-history-parameters number-of-intervals non-valid-intervals Defines common parameters required when defining 15 minute history performance counters.
performance-15min-history-parameters number-of-intervals non-valid-intervals Defines common parameters required when defining 15 minute history performance counters.
performance-24hr-history-parameters number-of-intervals non-valid-intervals Defines common parameters required when defining 24 hour history performance counters.
performance-24hr-history-parameters number-of-intervals non-valid-intervals Defines common parameters required when defining 24 hour history performance counters.
performance-history-15min-interval-parameters measured-timeinvalid-data-flag time-stamp Defines common parameters required when defining 15 minute interval history performance counters.
performance-history-15min-interval-parameters measured-timeinvalid-data-flag time-stamp Defines common parameters required when defining 15 minute interval history performance counters.
performance-history-24hr-interval-parameters measured-timeinvalid-data-flag time-stamp Defines common parameters required when defining 24 hour interval history performance counters.
performance-history-24hr-interval-parameters measured-timeinvalid-data-flag time-stamp Defines common parameters required when defining 24 hour interval history performance counters.
performance-history-interval-parameters invalid-data-flag time-stamp Defines common parameters required when defining history interval performance counters.
performance-history-interval-parameters invalid-data-flag time-stamp Defines common parameters required when defining history interval performance counters.
performance-history-measured-time measured-time Reports the measured time for a given interval.
performance-history-measured-time measured-time Reports the measured time for a given interval.
rpf-far-end-line-diagnostics latest-pse-start-up-failure-cause latest-pse-shutdown-cause Reverse Power Feeding (RPF) line level diagnostics.
rpf-far-end-line-diagnostics latest-pse-start-up-failure-cause latest-pse-shutdown-cause Reverse Power Feeding (RPF) line level diagnostics.
rpf-far-end-line-inventory nt-integrated battery-backup-available prp-capability Reverse Power Feeding (RPF) far-end line level inventory.
rpf-far-end-line-inventory nt-integrated battery-backup-available prp-capability Reverse Power Feeding (RPF) far-end line level inventory.
rpf-far-end-line-status actual-power-class rpf-state Reverse Power Feeding (RPF) far-end line level status.
rpf-far-end-line-status actual-power-class rpf-state Reverse Power Feeding (RPF) far-end line level status.
rpf-line-performance intervals-15min intervals-24hr Reverse Power Feeding (RPF) line level performance.
rpf-line-performance intervals-15min intervals-24hr Reverse Power Feeding (RPF) line level performance.
rpf-near-end-line-inventory reconfiguration-capability Reverse Power Feeding (RPF) near-end line level inventory.
rpf-near-end-line-inventory reconfiguration-capability Reverse Power Feeding (RPF) near-end line level inventory.
rpf-near-end-line-status actual-power-class rpf-state reconfiguration-state prp-error-status line-error-status Reverse Power Feeding (RPF) near-end line level status.
rpf-near-end-line-status actual-power-class rpf-state reconfiguration-state prp-error-status line-error-status Reverse Power Feeding (RPF) near-end line level status.

© 2023 YumaWorks, Inc. All rights reserved.