This submodule contains a collection of YANG definitions for managing Time Division Duplexing (TDD) profiles. Copyright (c) 201...
Version: 2022-06-13
submodule bbf-fast-tdd-profile-body { yang-version 1.1; belongs-to bbf-fast { prefix bbf-fast; } include bbf-fast-base; organization "Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area"; contact "Comments or questions about this Broadband Forum YANG module should be directed to <mailto:help@broadband-forum.org>. Editor: Ken Kerpez, ASSIA, Inc. Editor: Joey Boyd, Adtran PS Leader: Joey Boyd, Adtran WA Director: Sven Ooghe, Nokia WA Director: Joey Boyd, Adtran"; description "This submodule contains a collection of YANG definitions for managing Time Division Duplexing (TDD) profiles. Copyright (c) 2016-2022 Broadband Forum Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The above license is used as a license under copyright only. Please reference the Forum IPR Policy for patent licensing terms <https://www.broadband-forum.org/ipr-policy>. Any moral rights which are necessary to exercise under the above license grant are also deemed granted under this license. This version of this YANG module is part of TR-355a4c1; see the TR itself for full legal notices."; revision "2022-06-13" { description "Amendment 4 Corrigendum 1. * Approval Date: 2022-06-13 * Publication Date: 2022-06-13."; reference "TR-355a4c1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-4.pdf>"; } revision "2022-05-23" { description "Amendment 4. * Approval Date: 2022-05-23 * Publication Date: 2022-05-23."; reference "TR-355a4: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-4.pdf>"; } revision "2020-10-13" { description "Amendment 3. * Approval Date: 2020-10-13 * Publication Date: 2020-10-13."; reference "TR-355a3: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-3.pdf>"; } revision "2020-01-17" { description "Amendment 2 Corrigendum 2. * Approval Date: 2020-01-17 * Publication Date: 2020-01-17."; reference "TR-355a2c2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-2.pdf>"; } revision "2019-10-21" { description "Amendment 2 Corrigendum 1. * Approval Date: 2019-10-21 * Publication Date: 2019-10-21."; reference "TR-355a2c1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/download/ TR-355_Amendment-2.pdf>"; } revision "2019-06-11" { description "Amendment 2. * Approval Date: 2019-06-11 * Publication Date: 2019-06-11."; reference "TR-355a2: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-2.pdf>"; } revision "2018-10-01" { description "Amendment 1. * Approval Date: 2018-10-01 * Publication Date: 2018-10-01."; reference "TR-355a1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Amendment-1.pdf>"; } revision "2017-03-13" { description "Corrigendum 1 (fixes to the initial revision). * Approval Date: see revision date above. * Publication Date: 2017-04-12."; reference "TR-355c1: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355_Corrigendum-1.pdf>"; } revision "2016-07-18" { description "Initial revision. * Approval Date: see revision date above. * Publication Date: 2016-08-05."; reference "TR-355: YANG Modules for FTTdp Management <https://www.broadband-forum.org/technical/download/ TR-355.pdf>"; } grouping time-division-duplexing-parameters { description "Time Division Duplexing (TDD) configuration parameters."; reference "ITU-T G.997.2 clause 7.1.1"; leaf total-symbol-periods { type uint8 { range "23 | 36"; } default "36"; description "Defines the total number of symbol periods in a Time Division Duplexing (TDD) frame."; reference "ITU-T G.997.2 clause 7.1.1.1 (MF); ITU-T G.9701 clause 10.5"; } leaf downstream-symbol-periods { type uint8 { range "6..32"; } must "(../total-symbol-periods = 23 and .>= 6 and .<= 19) or (../total-symbol-periods = 36 and .>= 10 and .<= 32)" { error-message "Either the 'total-symbole-periods' is 23 and 'downstream-symbol-periods' is not in the range of 6 to 19 or 'total-symbol-periods' is 36 and 'downstream-symbol-periods' is not in the range of 10 to 32."; description "If the total symbol periods is 23, the number of downstream symbol periods must be between 6 to 19 inclusive. If the total symbol periods is 36, the number of downstream symbol periods must be between 10 to 32 inclusive."; } default "28"; description "Defines the total number of symbol positions in a Time Division Duplexing (TDD) frame allocated for downstream transmission. The total number of symbol positions in a TDD frame allocated for upstream transmission is calculated as Mus = MF-1-Mds."; reference "ITU-T G.997.2 clause 7.1.1.2 (Mds); ITU-T G.9701 clause 10.5"; } leaf cyclic-extension { type uint8 { range "4 | 8 | 10 | 12 | 14 | 16 | 20 | 24 | 30 | 33"; } units "n samples"; default "10"; description "Defines the cyclic extension(Lcp) to be used. The units are in N/64 samples, where N = index of the highest supported downstream data-bearing sub-carrier as defined for the enabled profile plus one."; reference "ITU-T G.997.2 clause 7.1.1.3 (CE); ITU-T G.9701 clause 10.4.4 and Table 6-1"; } container dynamic-time-assignment { if-feature bbf-fast:dta; description "Configuration of Dynamic Time Assignement (DTA)."; leaf dta-allowed { type enumeration { enum "none" { value 0; description "Dynamic Time Assignment (DTA) is not allowed."; } enum "idta" { value 1; description "Operation according to ITU-T G.9701 Annex X (iDTA) is allowed. If 'annex-x-mode' in the vectoring profile is configured as 'forbidden', then this value must not be configured."; } enum "cdta" { value 2; description "Operation according to ITU-T G.9701 Annex D (cDTA) is allowed. If 'annex-d-mode' in the vectoring profile is configured as 'forbidden', then this value must not be configured."; } } default "none"; description "The type of Dynamic Time Assignment (DTA) allowed."; reference "ITU-T G.997.2 clauses T.2.1.2 (IDTA_ALLOWED) and T.2.1.4 (CDTA_ALLOWED); ITU-T G.9701 clauses X.6.7.2, T.2.2, D.5.7.2 and T.2.2.1"; } leaf preferred-mds { type uint8 { range "5..31"; } must "(((../dta-allowed='idta' and ../../total-symbol-periods = 23 and .>= 5 and .<= 17) or (../dta-allowed='idta' and ../../total-symbol-periods = 36 and .>= 5 and .<= 30) or (../dta-allowed='cdta' and ../../total-symbol-periods = 23 and .>= 6 and .<= 19) or (../dta-allowed='cdta' and ../../total-symbol-periods = 36 and .>= 10 and .<= 31)) and (. >= ../minimum-mds) and (. <= ../maximum-mds)) or ../dta-allowed='none'" { error-message "'preferred-mds' is either less than 'minimum-mds' or is greater than 'maximum-mds' depending on the configured values of 'dta-allowed' and 'total-symbol-periods'."; description "The preferred Mds for Dynamic Time Assignment (DTA) must be equal to or higher than the minimum Mds for DTA and less than or equal to the maximum Mds for DTA. The valid range depends on total symbol period (MF) and DTA type allowed."; } default "28"; description "Provides the number of downstream symbol positions in a Time Division Duplexing (TDD) frame requested by the Dynamic Resource Allocation (DRA) at the first opportunity upon entering showtime of a line on which Dynamic Time Assignment (DTA) operation is enabled. If MF=23, a value different from the default value needs to be configured."; reference "ITU-T G.997.2 clause T.2.2.1 (DTA_PREF_Mds); ITU-T G.9701 clause T.2.3"; } leaf maximum-step-size { type uint8 { range "1..25"; } must "(../dta-allowed='idta' and ../../total-symbol-periods = 23 and .>= 1 and .<= 12) or (../dta-allowed='idta' and ../../total-symbol-periods = 36 and .>= 1 and .<= 25) or (../dta-allowed='cdta' and ../../total-symbol-periods = 23 and .>= 1 and .<= 13) or (../dta-allowed='cdta' and ../../total-symbol-periods = 36 and .>= 1 and .<= 21) or ../dta-allowed='none'" { error-message "'maximum-step-size' is not valid based on the configured values of 'dta-allowed' and 'total-symbol-periods'."; description "The maximum step size must be restricted to the valid range depending on total symbol periods (MF) and Dynamic Time Assignment (DTA) type allowed."; } default "25"; description "Defines the maximum step size for Mds requested by the DRA for a single Dynamic Time Assignment (DTA) update. For configurations other than independent Dynamic Time Assignment (iDTA) allowed with MF=36, a value different from the default value needs to be configured."; reference "ITU-T G.997.2 clause T.2.2.2 (DTA_SMAX); ITU-T G.9701 clause T.2.3"; } leaf minimum-time-between-updates { type uint16 { range "0..16383"; } units "0.01 seconds"; default "0"; description "Provides the minimum time between any two successive Dynamic Time Assignment (DTA) updates during showtime."; reference "ITU-T G.997.2 clause T.2.2.8 (DTA_MIN_TIME); ITU-T G.9701 clause T.2.10"; } leaf minimum-mds { type uint8 { range "5..31"; } must "(((../dta-allowed='idta' and ../../total-symbol-periods = 23 and .>= 5 and .<= 17) or (../dta-allowed='idta' and ../../total-symbol-periods = 36 and .>= 5 and .<= 30) or (../dta-allowed='cdta' and ../../total-symbol-periods = 23 and .>= 6 and .<= 19) or (../dta-allowed='cdta' and ../../total-symbol-periods = 36 and .>= 5 and .<= 31)) and . <= ../../downstream-symbol-periods) or ../dta-allowed='none'" { error-message "'minimum-mds' is not valid based on the configured values of 'dta-allowed' and 'total-symbol-periods'."; description "The minimum Mds must be restricted to the valid range depending on total symbol periods (MF), Dynamic Time Assignment (DTA) type allowed, and downstream symbol periods."; } default "5"; description "Provides the minimum number of downstream symbol positions Mds in a Time Division Duplexing (TDD) frame that shall be requested by the Dynamic Time Assignment (DTA). For configurations with cDTA allowed, a value different from the default value needs to be configured."; reference "ITU-T G.997.2 clause T.2.2.3 (DTA_MIN_Mds); ITU-T G.9701 clause T.2.5"; } leaf maximum-mds { type uint8 { range "5..31"; } must "(((../dta-allowed='idta' and ../../total-symbol-periods = 23 and .>= 5 and .<= 17) or (../dta-allowed='idta' and ../../total-symbol-periods = 36 and .>= 5 and .<= 30) or (../dta-allowed='cdta' and ../../total-symbol-periods = 23 and .>= 6 and .<= 19) or (../dta-allowed='cdta' and ../../total-symbol-periods = 36 and .>= 10 and .<= 31)) and . >= ../../downstream-symbol-periods) or ../dta-allowed='none'" { error-message "'maximum-mds' is not valid based on the configured values of 'dta-allowed' and 'total-symbol-periods'."; description "The maximum Mds must be restricted to the valid range depending on total symbol periods (MF), Dynamic Time Assignment (DTA) type allowed, and downstream symbol periods."; } default "30"; description "Provides the maximum number of downstream symbol positions Mds in a Time Division Duplexing (TDD) frame that shall be requested by the Dynamic Resource Allocation (DRA). For configurations with MF=23, a value different from the default value needs to be configured."; reference "ITU-T G.997.2 clause T.2.2.4 (DTA_MAX_Mds); ITU-T G.9701 clauses X.6.7.4 and T.2.6"; } leaf cdta-procedure-control { when "../dta-allowed='cdta'" { description "Only applicable when Coordinated Dynamic Time Assignment (cDTA) is configured."; } if-feature bbf-fast:annex-d; type enumeration { enum "one-or-two-step" { value 0; description "Dynamic Resource Allocation (DRA) is allowed to use the one-step or two-step Coordinated Dynamic Time Assignment (cDTA) procedure."; } enum "one-step-only" { value 1; description "Dynamic Resource Allocation (DRA) shall use the one-step Coordinated Dynamic Time Assignment (cDTA) procedure only."; } enum "two-step-only" { value 2; description "Dynamic Resource Allocation (DRA) shall use the two-step procedure only. This value is intended to be used for test purposes."; } } default "one-or-two-step"; description "Provides the procedure type that the Dynamic Resource Allocation (DRA) is allowed to apply. If the CDTA_PROC_CTRL is set to 2 and the FAST Transceiver Unit - central Office (FTU-O) does not support the two-step procedure, no Coordinated Dynamic Time Assignment (cDTA) procedure is triggered by the DRA."; reference "ITU-T G.997.2 clause T.2.7 (CDTA_PROC_CTRL); ITU-T G.9701 clauses T.2.9 and Y.5.6"; } } // container dynamic-time-assignment } // grouping time-division-duplexing-parameters grouping tdd-profile { description "Defines the contents of a Time Division Duplexing (TDD) Profile."; uses time-division-duplexing-parameters; } // grouping tdd-profile } // submodule bbf-fast-tdd-profile-body
© 2024 YumaWorks, Inc. All rights reserved.