SnmpAdminString |
string |
An octet string containing administrative
information, preferably in human-readable form.
To facilitate internationalization, this
information is represented using the ISO/IEC
IS 10646-1 character set, encoded as an octet
string using the UTF-8 transformation format
described in [RFC2279].
Since additional code points are added by
amendments to the 10646 standard from time
to time, implementations must be prepared to
encounter any code point from 0x00000000 to
0x7fffffff. Byte sequences that do not
correspond to the valid UTF-8 encoding of a
code point or are outside this range are
prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline,
the control code sequence CR LF should be used.
The use of leading or trailing white space should
be avoided.
For code points not directly supported by user
interface hardware or software, an alternative
means of entry and display, such as hexadecimal,
may be provided.
For information encoded in 7-bit US-ASCII,
the UTF-8 encoding is identical to the
US-ASCII encoding.
UTF-8 may require multiple bytes to represent a
single character / code point; thus the length
of this object in octets may be different from
the number of characters encoded. Similarly,
size constraints refer to the number of encoded
octets, not the number of characters represented
by an encoding.
Note that when this TC is used for an object that
is used or envisioned to be used as an index, then
a SIZE restriction MUST be specified so that the
number of sub-identifiers for any object instance
does not exceed the limit of 128, as defined by
[RFC3416].
Note that the size of an SnmpAdminString object is
measured in octets, not characters. |
SnmpEngineID |
binary |
An SNMP engine's administratively-unique identifier.
Objects of this type are for identification, not for
addressing, even though it is possible that an
address may have been used in the generation of
a specific value.
The value for this object may not be all zeros or
all 'ff'H or the empty (zero length) string.
The initial value for this object may be configured
via an operator console entry or via an algorithmic
function. In the latter case, the following
example algorithm is recommended.
In cases where there are multiple engines on the
same system, the use of this algorithm is NOT
appropriate, as it would result in all of those
engines ending up with the same ID value.
1) The very first bit is used to indicate how the
rest of the data is composed.
0 - as defined by enterprise using former methods
that existed before SNMPv3. See item 2 below.
1 - as defined by this architecture, see item 3
below.
Note that this allows existing uses of the
engineID (also known as AgentID [RFC1910]) to
co-exist with any new uses.
2) The snmpEngineID has a length of 12 octets.
The first four octets are set to the binary
equivalent of the agent's SNMP management
private enterprise number as assigned by the
Internet Assigned Numbers Authority (IANA).
For example, if Acme Networks has been assigned
{ enterprises 696 }, the first four octets would
be assigned '000002b8'H.
The remaining eight octets are determined via
one or more enterprise-specific methods. Such
methods must be designed so as to maximize the
possibility that the value of this object will
be unique in the agent's administrative domain.
For example, it may be the IP address of the SNMP
entity, or the MAC address of one of the
interfaces, with each address suitably padded
with random octets. If multiple methods are
defined, then it is recommended that the first
octet indicate the method being used and the
remaining octets be a function of the method.
3) The length of the octet string varies.
The first four octets are set to the binary
equivalent of the agent's SNMP management
private enterprise number as assigned by the
Internet Assigned Numbers Authority (IANA).
For example, if Acme Networks has been assigned
{ enterprises 696 }, the first four octets would
be assigned '000002b8'H.
The very first bit is set to 1. For example, the
above value for Acme Networks now changes to be
'800002b8'H.
The fifth octet indicates how the rest (6th and
following octets) are formatted. The values for
the fifth octet are:
0 - reserved, unused.
1 - IPv4 address (4 octets)
lowest non-special IP address
2 - IPv6 address (16 octets)
lowest non-special IP address
3 - MAC address (6 octets)
lowest IEEE MAC address, canonical
order
4 - Text, administratively assigned
Maximum remaining length 27
5 - Octets, administratively assigned
Maximum remaining length 27
6-127 - reserved, unused
128-255 - as defined by the enterprise
Maximum remaining length 27 |
SnmpMessageProcessingModel |
int32 |
An identifier that uniquely identifies a Message
Processing Model of the Message Processing
Subsystem within this SNMP Management Architecture.
The values for messageProcessingModel are
allocated as follows:
- Values between 0 and 255, inclusive, are
reserved for standards-track Message Processing
Models and are managed by the Internet Assigned
Numbers Authority (IANA).
- Values greater than 255 are allocated to
enterprise-specific Message Processing Models.
An enterprise messageProcessingModel value is
defined to be:
enterpriseID * 256 +
messageProcessingModel within enterprise
For example, the fourth Message Processing Model
defined by the enterprise whose enterpriseID
is 1 would be 259.
This scheme for allocating messageProcessingModel
values allows for a maximum of 255 standards-
based Message Processing Models, and for a
maximum of 256 Message Processing Models per
enterprise.
It is believed that the assignment of new
messageProcessingModel values will be rare
in practice because the larger the number of
simultaneously utilized Message Processing Models,
the larger the chance that interoperability
will suffer. It is believed that such a range
will be sufficient. In the unlikely event that
the standards committee finds this number to be
insufficient over time, an enterprise number
can be allocated to obtain an additional 256
possible values.
Note that the most significant bit must be zero;
hence, there are 23 bits allocated for various
organizations to design and define non-standard
messageProcessingModels. This limits the ability
to define new proprietary implementations of
Message Processing Models to the first 8,388,608
enterprises.
It is worthwhile to note that, in its encoded
form, the messageProcessingModel value will
normally require only a single byte since, in
practice, the leftmost bits will be zero for
most messages and sign extension is suppressed
by the encoding rules.
As of this writing, there are several values of
messageProcessingModel defined for use with SNMP.
They are as follows:
0 reserved for SNMPv1
1 reserved for SNMPv2c
2 reserved for SNMPv2u and SNMPv2*
3 reserved for SNMPv3 |
SnmpSecurityLevel |
enumeration |
A Level of Security at which SNMP messages can be
sent or with which operations are being processed;
in particular, one of:
noAuthNoPriv - without authentication and
without privacy,
authNoPriv - with authentication but
without privacy,
authPriv - with authentication and
with privacy.
These three values are ordered such that
noAuthNoPriv is less than authNoPriv and
authNoPriv is less than authPriv. |
SnmpSecurityModel |
int32 |
An identifier that uniquely identifies a
Security Model of the Security Subsystem within
this SNMP Management Architecture.
The values for securityModel are allocated as
follows:
- The zero value does not identify any particular
security model.
- Values between 1 and 255, inclusive, are reserved
for standards-track Security Models and are
managed by the Internet Assigned Numbers Authority
(IANA).
- Values greater than 255 are allocated to
enterprise-specific Security Models. An
enterprise-specific securityModel value is defined
to be:
enterpriseID * 256 + security model within
enterprise
For example, the fourth Security Model defined by
the enterprise whose enterpriseID is 1 would be
259.
This scheme for allocation of securityModel
values allows for a maximum of 255 standards-
based Security Models, and for a maximum of
256 Security Models per enterprise.
It is believed that the assignment of new
securityModel values will be rare in practice
because the larger the number of simultaneously
utilized Security Models, the larger the
chance that interoperability will suffer.
Consequently, it is believed that such a range
will be sufficient. In the unlikely event that
the standards committee finds this number to be
insufficient over time, an enterprise number
can be allocated to obtain an additional 256
possible values.
Note that the most significant bit must be zero;
hence, there are 23 bits allocated for various
organizations to design and define non-standard
securityModels. This limits the ability to
define new proprietary implementations of Security
Models to the first 8,388,608 enterprises.
It is worthwhile to note that, in its encoded
form, the securityModel value will normally
require only a single byte since, in practice,
the leftmost bits will be zero for most messages
and sign extension is suppressed by the encoding
rules.
As of this writing, there are several values
of securityModel defined for use with SNMP or
reserved for use with supporting MIB objects.
They are as follows:
0 reserved for 'any'
1 reserved for SNMPv1
2 reserved for SNMPv2c
3 User-Based Security Model (USM) |